SCSI Channel MAP
53
6-00020-02
SNC 5100
Check SCSI Bus Termination
Caution
If in this procedure you determine that you need to remove a SCSI 
cable or terminator, all I/O to the SNC 5100 must be stopped and 
the SNC 5100 must be turned off.
Step 1.
Verify the termination for the end device attached to the channel in 
question.
The last physical device on a chain of SCSI devices needs to be 
terminated.
If the end device has internal termination, be sure it is enabled.
Otherwise check that an external terminator is attached to the 
device.
A Differential (DE) terminator on a Single Ended (SE) bus or an SE 
terminator on a DE bus will cause the bus to be unusable. 
Step 2.
Verify the termination for the other devices attached to the channel 
in question.
Check that all SCSI devices other than the end devices have internal 
termination disabled.
A Differential (DE) terminator on a Single Ended (SE) bus or an SE 
terminator on a DE bus will cause the bus to be unusable.
Step 3.
If there are SCSI termination problems, power down the SNC 5100 
down and correct them. 
If you corrected SCSI termination problems, go to 
If SCSI termination is OK, go to 
Step 4.
If you powered down the SNC 5100 down, turn it back on.