ADIC SNC 5100 User Manual

Page of 228
Removing and Replacing the Unit
83
6-00020-02
SNC 5100
Caution
Shut down the host systems to ensure that all I/O through the SNC 5100 has 
stopped.
Step 1.
Verify that the latest configuration has been saved.
For more information on saving the configuration, see the ADIC 
Management Console User Guide
.
Step 2.
Shut the SNC 5100 down and disconnect the power cord.
Step 3.
For each cable attached to the SNC 5100, repeat the following:
-
Remove the cable.
-
Mark what the cable was connected to (for example, SNC 5100 
number 3, SCSI channel 1).
-
If the final cable has been removed, then return to the MAP that 
sent you here, or continue with "Removing and Replacing the 
Unit"
.
Removing and Replacing the Unit
Caution
Follow all ESD-sensitive parts procedures while performing this procedure. 
For ESD information, see “Handling Electrostatic Discharge-Sensitive Parts” 
on page 81.
This procedure describes how to remove and replace the SNC 5100.
Removing the SNC 5100
Step 1.
Step 2.
After the final cable has been removed, pop off the plastic 
rack-mount bezel, if installed on your unit. Pull it straight out to 
detach it. 
Step 3.
Unscrew the four 4-40 x 3/8" screws that hold the units to the rack 
bracket.