ADIC FastStor Mass Storage Device User Manual

Page of 68
 
 
Operation and Maintenance
 
31
 
The following table tells you when to use the cleaning tape: 
If . . . 
It means . . . 
You should . . . 
1. The CT field appears on the 
Operator’s Panel LCD 
The drive head needs cleaning or the 
tape is bad 
Use the cleaning tape to clean the drive 
head.  
When cleaning is complete, log the cleaning 
onto the label. 
2.  A data cartridge causes the CT 
field to appear on the Operator’s 
Panel LCD 
The data cartridge may be damaged 
Back up the data from this cartridge onto 
another cartridge, it may be damaged. A 
damaged cartridge may cause unnecessary 
use of the cleaning cartridge. 
3.  The CT field re-appears after 
performing a cleaning and 
reloading the data cartridge. 
Cleaning was not accomplished 
because the cleaning tape has 
exhausted all cleaning cycles. 
OR 
The data cartridge may be damaged 
Replace the cleaning cartridge. 
Back up the data from this cartridge onto 
another cartridge, it may be damaged. A 
damaged cartridge may cause unnecessary 
use of the cleaning cartridge. 
 
 
Drive Head Cleaning Procedure 
The following procedure is to be used only if your application does not support an auto clean cycle and you choose not to use the 
AUTOCLEAN feature (refer to Chapter 4 for a detailed description of the AUTOCLEAN feature), or the CLEAN dRV function 
under the DIAGNOSTICS MENU (refer to Chapter 4 for a detailed description of the CLEAN dRV function). 
Manually Cleaning the Drive Head 
Notes 
 
 
To initiate the cleaning cycle manually you must be aware of the present state of the FastStor and the drive that you wish 
to clean. The drive and storage slot 2 must be empty. 
 
 
If a cartridge is present in the drive, you must first use the Mode 1B - EJECT dRV operation to remove the cartridge. If 
necessary, manually remove the data cartridge from slot 2. You can then proceed with these instructions. 
Caution 
Cleaning cartridges are considerably more abrasive to the drive's recording 
head than standard data cartridges. Usage should be kept within the 
recommended limits. 
  Open the front door of the FastStor. 
  Insert the cleaning cartridge into an empty storage slot. 
  Use Mode 1A – LOAd dRV to load the cleaning tape into the drive. 
The cleaning cycle will be performed. When cleaning is completed, perform the following instructions: 
  Use Mode 1B – EJECT dRV to unload the cleaning tape from the drive and place it back in the storage slot. 
  Remove the cleaning cartridge and check a usage box on the label. 
  To resume normal operation, close the door and lock it.