General safety InforMatIon
when servicing this unit, verify the power to the unit is turned off prior to opening the control cabinet door.
precautIons
DO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN UNDER 
WATER.  Immediately  call  a  qualified  service  technician  to  inspect 
the appliance and to replace any part of the control system which 
has been under water.
If the unit is exposed to the following, do not operate heater until all 
corrective steps have been made by a qualified service agency.
1.  External fire.
2.  Damage.
3.  Firing without water.
GroundInG InstructIons
This water heater must be grounded in accordance with the National 
Electrical Code and/or local codes. These must be followed in all cases. 
Failure to ground this water heater properly may also cause erratic 
control system operation on ELECTRONIC CONTROL models.
This water heater must be connected to a grounded metal, permanent 
wiring system, or an equipment grounding conductor must be run with 
the  circuit  conductors  and  connected  to  the  equipment  grounding 
terminal or lead on the water heater.
hydroGen Gas (flaMMaBle)
Hydrogen gas can be produced in a hot water system served by this heater 
that has not been used for a long period of time (generally two weeks or 
more). Hydrogen gas is extremely flammable. To reduce the risk of injury 
under these conditions, it is recommended that the hot water faucet be 
opened for several minutes at the kitchen sink before using any electrical 
appliance connected to the hot water system. If hydrogen is present there 
will probably be an unusual sound such as air escaping through the pipe 
as the water begins to flow. THERE SHOULD BE NO SMOKING OR 