CoMPlIanCe
31.11  Model 463G NET with CELL as Alternate Primary and Dialer Backup, Standard or 
Encrypted Line Security 
Standard or Encrypted Line Security is provided using NET communication with CELL as an alternate primary
and with digital dialer as a backup. XR500 network communication is used as primary with a 6 minute
check-in when armed, and a random check-in over a 60 minute period when disarmed. CELL is the backup
path and set to daily test. Should the NET primary path become disabled, CELL adapts the same check-in
time programmed for the primary communication and becomes an alternate primary path. The dialer path
is used as the backup if both NET and CELL fail to receive acknowledgement from the receiver.
This method of operation causes the CELL alternate primary to adapt to the 6 minute NET primary check-in
rate when the NET primary is unavailable maintaining line supervision and precludes the need for a central
station runner to respond to the NET primary failure.
Path 1 programming 
Path 2 programming 
Path 3 programming 
Comm Type: = NET
Comm Type: = CELL
Comm Type: = DD 
Path Type: = Primary 
Path Type: = Backup (operates
as alternate primary) 
Path Type: = Backup
(operates as second 
method) 
Test Rpt: = NO
Test Rpt: = YES
Test Rpt: = YES
Checkin: = 6 minute, or RND
(random) 
Test Freq: = Daily 
Test Freq: = Daily 
Fail Time: = 6 minute, or RND
(random) 
Checkin: = ADAPT 
Duplicate Alarms: = YES
Encrypt: = NO or YES*
Encrypt: = NO or YES*
Sub Code: = YES
Sub Code: = Shared
*For Encrypted Line Security, program a Passphrase in Network Options.
31.12  Model 463G NET with CELL as Backup and Adaptive Primary, Standard or 
Encrypted Line Security 
Standard or Encrypted Line Security is provided when programmed using NET communication and CELL as
backup and as needed adapts and takes over as primary.  XR500 network communication is used as primary 
with a 6 minute check-in when armed, and a random check-in over a 60 minute period when disarmed.
CELL is the backup path and set to daily test. Should the primary path become disabled, the CELL adapts
to a special 3 minute check-in time and because of that check-in rate becomes the primary without the
requirement of a backup. This method of operation causes the CELL backup to adapt to the 3 minute check-
in rate when the NET primary is unavailable becoming a standalone primary without the need for a backup.
This maintains line supervision and precludes the need for a central station runner to respond to the NET
primary failure.
Path 1 programming 
Path 2 programming 
Comm Type: = NET
Comm Type: = CELL
Path Type: = Primary 
Path Type: = Backup (operates as second
method) 
Test Rpt: = NO
Test Rpt: = YES
Checkin: = 6 minute, or RND
(random) 
Test Freq: = Daily 
Fail Time: = 6 minute, or RND
(random) 
Checkin: = ADAPT3
Encrypt: = NO or YES*
Encrypt: = NO or YES*
Sub Code: = YES
Duplicate Alarms: = YES
Sub Code: = Shared
*For Encrypted Line Security, program a Passphrase in Network Options.