Dimplex WFC 3NB User Manual

Page of 4
350mm min
120mm
350mm
575mm
Installation and Operating Instructions
Dimplex Wall-mounted Fan Convector  
 
 
 
 
  
08/18724/2     Issue 2 
 
 
          
Models : WFC 3NB and WFC 3NS 
 
 
 
 
 
 
 
 
 
Dimensions 
 
 
Model(s) Specification 
 
WFC 3NB 
3kW, Switch, Thermostat & Neon - Black 
 
WFC 3NS 
3kW, Switch, Thermostat & Neon - Silver 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 Fig. 1 
 
 
 
 
 
Installation 
 
Before undertaking installation work, ensure the electricity 
supply is disconnected from any relevant fixed wiring
 
Supply cable is not provided with this appliance, and a 
competent electrician should therefore install it. 
The appliance must be fitted horizontally with the cable or 
conduit entry at bottom right. It should be mounted such that the 
underside is at least 350mm above the floor and the top of the 
heater is 150mm below any overhanging shelf or obstruction. 
 
 
This heater must be used on an A.C.~ supply only and the 
voltage marked on the heater must correspond to the 
supply voltage. 
 
To comply with the I.E.E. Wiring Regulations, the appliance 
must be earthed; the supply circuit must be adequate for the 
input of the appliance, and the circuit protected by a suitable 
13A fuse. A suitable termination to the fixed wiring of the 
premises must be provided adjacent to the final position of the 
appliance. In this instance, such a termination can be a double-
pole switch with a contact separation of at least 3mm in all 
poles. 
 
The heater must not be located immediately below a fixed 
socket-outlet
 
 
Electrical 
 
WARNING : THIS APPLIANCE MUST BE EARTHED. 
 
After ensuring the electricity supply is not live, electrical 
connections can be made, either to an adjacent double-pole 
switch having a contact separation of at least 3mm in all poles 
or to a plug-top for use in a standard 13A socket. 
If the latter: Connect Green  and Yellow wire to 
marked or   
 
 
 
 
 
 
 
 
 
 
 
 
plug terminal 
   Green or Green and Yellow. Connect Blue 
wire to plug terminal marked N or Black. Connect Brown wire 
to plug terminal marked L or Red
Refit cover, first hooking top over the back of the unit and then 
securing the bottom by refitting the two screws under the 
bottom edge. The appliance is now ready for use and the 
electricity supply can be reinstated. 
 
 
 
 
 
THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE
.
THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE
.
 
IMPORTANT SAFETY ADVICE
 
 
WARNING – THIS APPLIANCE MUST NOT BE USED IN 
A BATHROOM. 
WARNING – DO NOT USE THIS HEATER IN THE 
IMMEDIATE SURROUNDINGS OF A BATH, A SHOWER 
OR A SWIMMING POOL. 
WARNING – THIS HEATER MUST NOT BE LOCATED 
IMMEDIATELY BELOW A FIXED SOCKET OUTLET. 
DO NOT USE THE HEATER UNTIL IT IS WALL 
MOUNTED CORRECTLY. 
The heater carries a warning 'Do Not Cover' to alert 
the user to the risk of overheating that exists if the 
heater is accidentally covered. 
NEVER cover or obstruct in any way the air inlet slots 
at the front of the heater or the heat outlet slots in the 
base of the heater. 
Keep combustible materials such as drapes and other 
furnishings clear from the front  of the heater. Do not 
use heater to dry your laundry. 
This appliance is not intended for use by children or 
other persons without assistance or supervision if 
their physical, sensory or mental capabilities prevent 
them from using it safely. Children should be 
supervised to ensure that they do not play with the 
appliance. 
If young children, the aged, or infirm  are likely to be 
left in the vicinity of the heater, we advise that 
adequate precautions should be taken. We 
recommend that a guard be fitted to ensure contact 
with the heater is avoided and objects cannot be 
inserted into the product. 
WARNING: In order to avoid a hazard due to 
inadvertent resetting of the thermal cut-out, this 
appliance must not be supplied through an external 
switching device, such as a timer, or connected to a 
circuit that is regularly switched on and off by the 
utility.Do not use where excessive dust or moisture is 
present. 
For further information, please contact our guard 
supplier direct on Tel. No. 01603 667957, or in the 
case of difficulty or for further advice contact the 
Customer Helpline.