2.6.2  Limit Switch Connector 
The limit switch connector is located at the upper left-hand corner of the 4404 circuit board and 
provides input to the circuit board from the limit switches. 
 
1. FULL 
LIMIT 
2. SLOW 
DOWN 
3. PARTIAL 
LIMIT 
4. SLOW 
DOWN 
5. FULL 
LIMIT 
6. LIMIT 
ENABLE 
7. LIMIT 
COMMON 
8. LIMIT 
COMMON 
 
2.6.3 Reversing 
Device 
Connector 
External entrapment prevention devices are connected here. 
 
1. OPEN 
PHOTO-BEAM 
This input is only active when the gate is in the opening cycle. An open photo-beam input 
during the opening cycle will cause the gate to stop. The gate will remain stopped until 
the photo-beam input is cleared, at which time the gate will resume the open cycle. 
2. CLOSE 
PHOTO-BEAM 
This input is only active when the gate is in the closing cycle. A close photo-beam input 
during the closing cycle will cause the gate to stop. The gate will remain stopped until the 
photo-beam input is cleared, at which time the gate will resume the close cycle. 
3. OPEN 
EDGE 
This input is only active when the gate is in the opening cycle. An open edge input during 
the opening cycle will cause the gate to stop and then reverse. 
 
If the gate reaches the full closed position, the gate will remain closed, ignore any 
maintained inputs and enter a soft shutdown condition.  NOTE: If the gate was initially 
activated by a time clock with a contact closure across the gate operator open input, this 
input will be ignored until another input (open loop, reverse loop. etc.) is received by the 
gate operator. 
 
If a close edge sensor is activated prior to the gate reaching the full closed position, the 
gate will stop and enter a soft shutdown condition. 
4. CLOSE 
EDGE 
This input is only active when the gate is in the closing cycle. A close edge input during 
the closing cycle will cause the gate to stop and then reverse. 
 
If the gate reaches the full open position, the timer will automatically close the gate (if it is 
turned on). Once the gate starts to close again, if the close edge input is activated a 
second time prior to the gate reaching the full closed position, the operator will stop and 
reverse and will enter a soft shutdown condition.  
 
If an open edge sensor is activated prior to the gate reaching the full open position, the 
gate will stop and enter a soft shutdown condition. 
5. COMMON 
Common terminal for the secondary entrapment protection device inputs. 
6. COMMON 
 
Page 
32
  