4.3 Manual Gate Operation 
This operator is equipped with a manual system that will allow the gate to be cranked open in the 
event of a power outage or equipment failure.   
NOTE: Never attempt to manually open any gate with an operator attached to it until you have 
verified that power to the operator has been shut-off. 
 
 
 
 
 
 
 
1.  Unlock the manual release access panel 
located on the top of the gate operator and 
open it.  Opening this access panel 
automatically activates an interlock switch 
that will prevent the gate operator motor 
from starting. 
2.  Insert the supplied manual hand crank into 
the access hole until it engages with the 
motor shaft.  Turn the crank to open the 
gate. 
3.  After the gate is opened, remove the crank 
and lock the access panel closed. 
 
 
 