Denso BHT-7500 User Manual

Page of 217
103
Chapter 2.  Getting Started the BHT and System Mode
BHT-7500W
       SET WEP KEY1
 
1:KEY SIZE
   
40
 128
 2:KEY
    **********         
                       
       SET WEP KEY1
 1:KEY SIZE
   
40
 128
 
2:KEY
    ABCDE12345          
                        
Defining WEP KEY 1
Selecting the "1:WEP KEY1" on the WEP KEY defi-
nition screen displays the "** Now Loading **."
After that, the screen shown at left will appear.
The "1:KEY SIZE" shows the current setting. The
"2:KEY" shows asterisks (*) of the key size to ob-
serve secrecy.
Select a desired item by using the numerical keys
or 
 and 
 keys.
To select the desired key size, use the Use the 
and 
 keys.
To enter the desired WEP key, select the "2:KEY"
and then press the  ENT  key. The screen enters
the alphanumeric entry mode in which a cursor
appears.
You may overwrite the current key with the de-
sired key, but may not edit or delete it.
For details about the WEP key, refer to Subsection
3.1.2.
If no asterisk (*) appears for the "2:KEY," it
means that the BHT-7500W has no WEP key
preset. When no WEP key can be defined,
the "40" is highlighted for the "1:KEY SIZE."
Shown at left is an WEP definition screen being
halfway through entry. In this example, the WEP
key is defined as "ABCDE12345."
An WEP should be a 10- or 26-digit hexadecimal
(with 0 through 9 and A through F).
If the key size is 40 or 128, the WEP key should be
10 or 26 digits, respectively.
To switch the entry mode between the numeric
mode (without guidance) and alphabet mode, press
the  SF  key. After completion of settings, press the
ENT  key.
In the entry mode, to delete a single character,
press the  BS  key ( SF  +  C  keys). To delete the
whole entry you made, press the  C  key.