Chapter 3.  Communications Operations of the BHT
3.4.2 Communications Parameters
In System Mode and user programs written in BHT-BASIC, you may set the communi-
cations parameters listed below.
Transmission Speed
2400, 9600, 19200, 38400,
57600, or 115200 bps
300, 600, 1200, 2400, 4800, 9600,
19200, 38400, 57600, or 115200 bps
Optical interface
Direct-connect interface
Communications Port
Character Length
8 bits
7 or 8 bits
Vertical Parity
None
Odd, even, or none
Stop Bit Length
1 bit
1 or 2 bits
In System Mode
Refer to Chapter 2, Subsection 2.5.3, [4.5], "Setting the communications environ-
ments."
In BHT-BASIC
To set the transmission speed, character length, vertical parity, and stop bit length (To
set the transmission speed only for the optical interface), use the 
OPEN
 
"COM:"
statement in BHT-BASIC.
OPEN
 
"COM:
 ... 
"
Opens the interface port selected in System Mode.
OPEN
 
"COM1:
 ... 
"
Opens the optical interface port for data transmission,
irrespective of the setting in System Mode.
OPEN
 
"COM2:
 ... 
"
Opens the direct-connect interface port for data trans-
mission, irrespective of the setting in System Mode.
Note that it is impossible to open both the optical interface port and the direct-connect
interface port concurrently.
Through the interface port opened by the 
OPEN
 
"COM:"
  statement, the 
XFILE
statement transmits a designated file.