(4)  Bar Codes
Bar code type
Bar dimensions
Readable range
Universal product codes
EAN-13
0.26 to 0.33 mm
0.8 to 1.0 magnifications
(10.24 to 12.99 mils)
EAN-8
0.26 to 0.46 mm
0.8 to 1.4 magnifications
(10.24 to 18.11 mils)
UPC-A
0.26 to 0.33 mm
0.8 to 1.0 magnification
(10.24 to 12.99 mils)
UPC-E
0.26 to 0.56 mm
0.8 to 1.7 magnifications
(10.24 to 22.05 mils)
Interleaved 2of5 (ITF)
2 to 34 digits*
Codabar (NW-7)
3 to 23 digits
Code 39
1 to 17 digits
Code 128 (EAN-128)
1 to 21 digits
* Only even-numbered digits
0.15 mm min.
(5.91 mils)
(5)  Multi-line Code Scanning
The BHT-100Q supports multi-line code scanning that can scan up to 3 lines of codes
out of universal product codes, Interleaved 2of5 (ITF), Codabar (NW-7), Code 39, and
Code 128 (EAN-128) at a time in the specified order.
The multi-line code scanning may be specified in user programs only.  For details, refer
to the "BHT-BASIC Programmer's Manual (BHT-100 series)."
(6)  Optical Properties Required
White cells (white bars):
Reflection intensity
45% min.
Black cells (black bars):
Reflection intensity
25% max.
PCS value
0.45 min.
All of the above values are under the following conditions:
- Ambient illuminance: 500 to 3000  x.
- Light source: Xenon lamp