Delta Tau GEO BRICK DRIVE User Manual

Page of 294
 Geo Brick Drive User Manual 
Pinouts and Software Setup 
 33 
J2: 24VDC Logic Power and Safe Torque Off (STO) 
J2  is  used  to  bring  the  24VDC  logic  power  into  the  Geo  Brick  Drive.  This  power  can  remain  on, 
regardless of the main AC/DC bus power input, allowing the digital control electronics to be active while 
the main motor power control is passive. 
 
J2, in the newer models of the Geo Brick Drive, is also used to wire the Safe Torque Off (STO) input.  
The  STO  allows  the  complete  (hardware)  disconnection  of  the  power  amplifiers  from  the  motors.  This 
mechanism  prevents  unintentional  “movement  of”  or  torque  output  to  the  motors  in  accordance  with 
IEC/EN safety standards. 
 
Newer  and  older  models  of  the  Geo  Brick  Drive  have  different  24V  logic  power  connector.  The  new 
connector  is  a  4-pin  (as  opposed  to  the  older  2-pin)  accommodating  the  STO  function.  It  is  a  Phoenix 
Contact terminal block (as opposed to the older Molex type) which allows for easier connection without 
the need of special crimping tools: 
 
 
The  newer  models  were  introduced  in  October  of  2012.  They  can  be  recognized  by  the  4-pin 
terminal block 24V logic with STO connector. 
 
 
The older models carry the Molex type 2-pin 24V logic connector (no STO).   
 
 
Note 
The Safe Torque Off (STO) feature is not available with older models 
of the Geo Brick Drive.      
 
It is recommended to use a protected power supply. In situations where the power supply is shared with 
other devices, it may be desirable to insert a filter before applying it to the Geo Brick Drive. 
 
If  multiple  drives  are  driven  out  of  the  same  24VDC  power  supply,  it  is  recommended  that  each  Geo 
Brick Drive be wired back to the power supply terminals independently. It is also recommended that the 
power  supply  be  sized  to  handle  the  instantaneous  inrush  current  required  to  start  up  the  DC-to-DC 
converter action inside the Drive(s). 
See electrical specifications.
 
 
 
Note 
The logic and STO connections can be made using a 22 gauge (AWG) 
wire.