NOTE:
NEVER TRANSPORT OR TURN THE APPLIANCE UPSIDE DOWN OR 
ON ITS SIDE. IF THIS OCCURS, WAIT 6 HOURS BEFORE TURNING 
THE APPLIANCE ON, 24 HOURS IS RECOMMENDED. After the unit 
has been on its side, oil needs to return to the compressor to 
ensure proper function.  Without allowing the unit this time (6-
24 hours) the unit may function for only a short time, and then 
the compressor will break down from lack of oil. 
TROUBLESHOOTING
PROBLEM 
CAUSE 
REMEDY
The air conditioning unit does not 
start.
No electricity.
It is not plugged into the outlet.
The safety device of the plug has tripped.
Restore electricity.
Plug into the outlet.
Reset the safety device, if problem per-
sists contact our toll free customer service
The air conditioning unit works for a 
short time only.
The air exhaust hose has a constriction.
The air exhaust hose is blocked.
There are  tight bends in the air exhaust 
hose.
Position the exhaust hose correctly.
Check there are no obstacles obstructing 
air discharge. 
Eliminate the tight bends.
The air conditioner works, but does 
not cool the room.
Window open.
The exhaust hose is detached.
Air filters clogged.
Close the window.
Connect the exhaust hose.
Clean or replace the filters.
Bad odor in the room.
The air purifying filters clogged.
Clean or replace the filter.
The air conditioner does not operate 
for about 3 minutes after turning it 
on.
The internal compressor safety device 
prevents the appliance from being 
restarted until three minutes have 
elapsed since it was last turned off.
Wait. This delay is part of normal
operation. 
 / 
PF
/   appears on the display. The appliance has a self diagnosis system 
to identify a number of malfunctions.
See the self-diagnosis chapter.