USER INTERFACE 
Ground
SC6000
A/B 
B/A 
GND 
VS_INPUTS 
Signal 
PWO 
 
Figure 44 - PNP Command Input Using System Power 
 
 
V
USER INTERFACE 
Ground
SC6000
A/B 
B/A 
GND 
VS_INPUTS 
Signal 
PWO 
 
Figure 45 - NPN Command Input Using System Power 
 
Isolation between the command logic and the scanner is maintained by powering the inputs 
with an external supply voltage (Vext). For convenience, the inputs can be powered using the 
VS_INPUTS signal on the SC6000 (pin 9). In this case, however, the device is no longer 
electrically isolated. The VS_INPUTS signal on the Extended I/O connector is short-circuit 
protected. 
 
The electrical features of these inputs are: 
Maximum voltage  30 V 
Maximum current  10 mA 
 
 
Outputs 
 
Six general purpose outputs are available. 
 
Pin Name 
Function 
OUT 1+ 
Configurable digital output 1 – positive pin 
19 
OUT 1- 
Configurable digital output 1 – negative pin 
OUT 2+ 
Configurable digital output 2 – positive pin 
20 
OUT 2- 
Configurable digital output 2 – negative pin 
OUT 3+ 
Configurable digital output 3 – positive pin 
21 
OUT 3- 
Configurable digital output 3 – negative pin 
10 
OUT 4+ 
Configurable digital output 4 – positive pin 
23 
OUT 4- 
Configurable digital output 4 – negative pin 
11 
OUT 5+ 
Configurable digital output 5 – positive pin 
24 
OUT 5- 
Configurable digital output 5 – negative pin 
12 
OUT 6+ 
Configurable digital output 6 – positive pin 
25 
OUT 6- 
Configurable digital output 6 – negative pin 
 
The function of all six outputs can be defined by the user. 
 