DataVideo MP-6000 Mk2 User Manual

Page of 49
39
Dip Switch 1 switches the MP 6000 between simple GPI control and RS 232 control. If Dip Switch 1 is Off 
(up) the MP 6000 responds to GPI, if it is On (down) then it responds to RS 232. The Front Panel and the 
GPI interface will be deactivated if RS 232 control is selected       
Dip Switches 
GPI Port 
DIP switch 
DIP switch 1 OFF (up),   
• GPI trigger is enabled. 
DIP switch 1 ON (When this function is turned on, the front 
panel and GPI function will be disabled. Only “EJECT” 
will work.)
•External RS 232 device control enabled. 
DIP switch 2 OFF (up) 
•GPI function is set to momentary closure (Pulse Trigger). 
DIP switch 2 ON 
•GPI function is set to maintained closure (Level Trigger). 
Note: Please make sure the MP 6000 is turned off before 
changing DIP switch settings.
The 3.5mm Stereo Jack Plug should be wired for contact closure between the inner pin and outer pin. The 
middle of the three contacts supplies a voltage which can be used to light an LED as an indication that the 
MP 6000 is recording.