Setting the Sensitivity
The Tru Pointe
®
 1100 always defaults to Sensitivity as the active mode.  After any adjustment has 
been made, it will store the setting in memory, and reset itself so that  and  adjust sensitivity.
Pressing the  and  arrows will adjust the sensitivity while in either sensor mode.  The prefi x 
on the alphanumeric display indicates the sensor being changed.  The display will read “A###” 
when the Airborne sensor is selected, or “P###” when the Touch Probe is selected.
Setting the Volume
Pressing the “MODE” button once will set the Tru Pointe
®
 1100 in the Volume Adjust Mode.  The 
alphanumeric display will read “VOL” as long as the MODE button is pressed.  When released 
it will show “V###” indicating the current volume setting.  Use the  and  buttons to make the 
adjustment.  The volume will change as the display changes from “V 000” to “V 255”.
NOTE:  Volume and sensitivity are not the same.  
Volume adjusts the loudness of the signal in the 
headset.  Sensitivity adjusts the meter’s reaction to the 
incoming signal. 
Selecting the Sensor
Press the “MODE” button until the alphanumeric display reads “AIR” or “PROB”. The instrument 
will delay 3 seconds after releasing the MODE button, for the sensor selection to be made by 
pressing the  or  button.
Adjusting the Display
The alphanumeric display offers three viewing options.  Continuous, Peak, and OFF.  Press the 
“MODE” button twice.  The display will read “DISP” until released, and then display the current 
setting.  Pressing the  or  buttons will scroll through the display options below.
“Cont” = Continuous, the alphanumeric display will show the level of the signal in real 
time.  
“Peak” = Peak Hold, the alphanumeric display will hold the highest reading for 3 sec-
onds.
“Off” = Turns the alphanumeric display off (with the exception of the “-“).  Since this 
display is not necessary for most airborne applications, turning it off can save 
battery life.
NOTE: The changes made will stay in the unit’s memory 
until they are updated. 
Checking the serial number
While the unit is powered OFF, hold down the “MODE” button.  Now turn the unit on while holding 
down the “MODE” button.  The Tru Pointe
®
 1100 will show its serial number in the alphanumeric 
display.