Chapter 5: Selecting Dipswitch Settings 
B&B Electronics  --  PO Box 1040  --  Ottawa, IL  61350 
PH (815) 433-5100  --  FAX (815)  433-5104
 
CHAPTER 5:  SELECTING DIPSWITCH SETTINGS 
 
The 232SPS2 is set up using an eight-position dipswitch. In 
order for the 232SPS2 to function properly, it must be set up to 
match your system's requirements. The following parameters on the 
232SPS2 are set on the dipswitch:  converter direction, baud rate, 
flow control, number of data bits, and the type of parity.  Each of the 
parameters are briefly described below. For specific parameter 
settings, refer to Table 5.1. 
 
Converter direction - Can operate as a parallel to serial 
converter or as a serial to parallel converter. The direction is 
set by dipswitch position 8. 
 
Baud rate - Can be set from 1200 to 115.2k baud. The baud 
rate is determined by dipswitch positions 1-3.   
 
Flow control - Can be set for DTR control or XON/XOFF 
control. The type of flow control used is determined by 
dipswitch position 4. 
 
Data bits - Can be set for 7 or 8 data bits. The number of 
data bits is determined by dipswitch position 5. 
 
Parity - Can be enable or disabled by dipswitch position 6. If 
parity is enabled, dipswitch position 7 determines whether 
the parity is even or odd. 
10 
Chapter 5: Selecting Dipswitch Settings 
232SPS2-3903 Manual 
B&B Electronics  --  PO Box 1040  --  Ottawa, IL  61350 
PH (815) 433-5100  --  FAX (815)  433-5104
 
Table 5.1 
 
 
Example #1 - Parallel to Serial Mode, hardware handshaking, 9600 
baud, 8 data bits, no parity 
Dipswitch position settings for Example #1 ("X" = don't care) 
 
  1   
 2 
  3 
 4 
  5 
  6 
 8 
ON 
  ON  OFF ON  OFF OFF X 
ON 
 
Example #2 - Serial to Parallel Mode, XON/XOFF flow control, 2400 
baud, 7 data bits, odd parity 
Dipswitch position settings for Example #2 
 
 1   
  2 
  3 
  4 
 5 
 6 
 7 
  8 
ON 
  OFF OFF OFF ON  ON  ON  OFF 
 
Setting DIP 
SWITCH 
POSITION 
 1 
1200 Baud 
OFF
OFF
OFF
2400 Baud 
ON 
OFF
OFF
4800 Baud 
OFF
ON 
OFF
9600 Baud 
ON 
ON 
OFF
19.2K Baud 
OFF
OFF
ON 
38.4 Baud 
ON 
OFF
ON 
57.6K Baud 
OFF
ON 
ON 
115.2K Baud
ON 
ON 
ON 
XON/XOFF 
X X X 
OFF
X X X X 
DTR 
control 
X X X 
ON 
X X X X 
Data 
bits X X X X 
OFF
X X X 
Data 
bits X X X X 
ON 
X X X 
No 
parity X X X X X 
OFF
X X 
Parity 
enable
X X X X X 
ON 
X X 
Even parity 
OFF
Odd parity 
ON 
Serial to Par.
OFF
Par. to Serial
ON