In the Commonwealth of Massachusetts, this 
appliance must be installed by a licensed plumber or 
gas fitter.
 WARNING
The Copper Brute II water heater 
must be installed 
in accordance with the procedures detailed in 
this manual, or the Bradford White warranty 
may be voided. The installation must conform to 
the requirements of the local jurisdiction having 
authority, and, in the United States, to the latest 
edition of the National Fuel Gas Code, ANSI 
Z223.1/NFPA54. In Canada, the installation must 
conform to the latest edition of the Natural Gas 
and Propane Installation Code, CSA B149.1 and/
or local codes. Where required by the authority 
having jurisdiction, the installation of Copper Brute 
II appliances must conform to the Standard for 
Controls and Safety Devices for Automatically Fired 
Boilers, ANSI/ASME CSD-1. Any modifications to 
the heater, its gas controls, or wiring may void the 
warranty. If field conditions require modifications, 
consult the factory representative before initiating 
such modifications.
1.1  Introduction
This manual provides information necessary 
for the installation, operation, and maintenance of 
the Bradford White Copper Brute II heaters. Read it 
carefully before installation.
All application and installation procedures 
should be reviewed completely before proceeding 
with the installation. Consult the Bradford White 
factory, or local factory representative, with any issues 
or questions regarding this equipment. Experience 
has shown that most operating issues are caused by 
improper installation.
The Copper Brute II is protected against over 
pressurization. A pressure relief valve is fitted to all 
appliances. It is installed on the outlet header, at the 
water outlet of the appliance.
IMPORTANT: The inlet gas pressure to the appliance 
must not exceed 13" W.C. (3.2kPa).
All installations must be made in accordance with:
1) In the U.S., the " National Fuel Gas 
Code"ANSI Z223.1/NFPA54, Latest Edition and all 
applicable local codes as required by the Authorities 
Having Jurisdiction (AHJ), or
2) In Canada, the "Natural Gas and Propane
Installation Code", CSA B149.1, latest edition and all 
applicable local codes as required by the AHJ.
All electrical wiring is to be done in accordance with:
1). In the U.S., the "National Electrical Code" 
(NEC), ANSI/NFPA 70, latest Edition and all 
applicable local codes as required by the AHJ, or
2). In Canada, the “Canadian Electrical Code 
- Part 1”, CSA STD. C22.1 and all applicable local 
codes as required by the AHJ.
This appliance must be electrically grounded in 
accordance with the applicable codes and standards 
referenced above.
1.2  Model Identification
Consult the rating plate on the unit. The 
following information describes the model number 
structure.
                  1      2      3           4          5      6     7      8          9              10             11                12                  13                14                15             16
                  B     W     C         V                                                                A                                                        2
SERIES
    B      W       C
USAGE
V
SIZE
    0        5       0        0
    0        7       5        0
    1        0       0        0
    1        2       5        0
    1        5       0        0
    1        7       5        0
    2        0       0        0
FUEL
N
P
ALTITUDE
A
FIRING
MODE
K (500/750)
N (1000)
L (1250-2000)
LOCATION
I
E
REVISION
2
HEAT
EXCHANGER
B
C
K
N
P
S
OPTIONS
CODE
X
J
L
PUMP
OPTIONS
X
H
N
S