Bosch GWH 2700 ES LP User Manual

Page of 60
6 720 608 542
Warning
3
1
Warning
For your safety
Do  not  store  or  use  gasoline  or  other  flammable,
combustible  or  corrosive  vapors  and  liquids  in  the
vicinity of this or any other appliance.
Warning: 
Carefully  plan  where  you
install  the  heater.  Correct  combustion
air supply and flue pipe installation are
very important. If a gas appliance is not
installed  correctly,  fatal  accidents  can
result,  such  as  carbon  monoxide
poisoning or fire.
Warning: 
Exhaust gas must be vented
to  outside  using  stainless  steel  vent
material  suitable  for  category  III  vent
systems and temperatures up to 480°F.
Vent piping must be sealed gas-tight to
prevent  possibility  of  flue  gas  spillage,
carbon monoxide emissions and risk of
fire,  resulting  in  severe  personal  injury
or  death.  Approved  vent  terminators
must be used when penetrating to the
outside.
Warning: 
Place the heater in a location
where water leaks will do NO DAMAGE
to adjacent areas or lower floors.
Warning: 
Field wiring connections and
electrical  grounding  must  comply  with
local codes, or in the absence of local
codes,  with  the  latest  edition  of  the
National Electric Code, ANSI/NFPA 70,
or in Canada, all electrical wiring must
comply  with  the  local  codes  and  the
Canadian Electrical Code, CSA C22.1
Part 1.
Warning: 
Shock hazard: line voltage is
present.  Before  servicing  the  water
heater, unplug power supply cord from
outlet.  Failure  to  do  so  could  result  in
severe personal injury or death.
Warning: 
The  heater  must  be
disconnected  from  the  gas  supply
piping  system  during  any  pressure
testing of that system at test pressures
equal to or more than 0.5 psig.
Warning: 
The  appliance  should  be
located in an area where leakage of the
heater  or  connections  will  not  result  in
damage  to  the  area  adjacent  to  the
appliance  or  to  lower  floors  of  the
structure.  When  such locations cannot
be  avoided,  it  is  recommended  that  a
suitable  drain  pan,  adequately  drained,
be  installed  under  the  appliance.  The
pan  must  not  restrict  combustion  air
flow.
Warning: 
The  maximum  inlet  gas
pressure  must  not  exceed  the  value
specified  by  the  manufacturer  and  that
the  minimum  value  listed  is  for  the
purposes of input adjustment.
Warning: 
If a water heater is installed in
a closed water supply system, such as
one having a backflow preventer in the
cold  water  supply  line,  means  shall  be
provided  to  control  thermal  expansion.
Contact  the  water  supplier  or  local
plumbing  inspector  on  how  to  control
this situation.
Warning: 
Keeping appliance area clear 
and free from combustible materials, 
gasoline and other flammable vapors 
and liquids.
Warning: 
Do not obstruct the flow of 
combustion and ventilation air.
Warning: 
Precautions  must  be  taken
prior  to  manually  operating  the  relief
valve  to  avoid  contact  with  hot  water
coming  out  of  the  relief  valve  and  to
prevent water damage.
Caution: 
Label  all  wires  prior  to
disconnection  when  servicing  controls.
Wiring  errors  can  use  improper  and
dangerous operation.
Verify proper operation after servicing.
Warning: 
In  order  for  the  freeze
prevention  kit  to  provide  adequate
protection,120V  AC  must  always  be
supplied to the water heater.