Bosch Security Systems | 04-2003 | 3922 988 43318 en
Digital Congress Network | Installation  and Operating Manual | Chapter 10 - Installation Techniques
en | 10-5
Trunk outlets and Tap-offs
10.3.2  Using Tap-Off unit LBB 4115/00
The Tap-off unit LBB 4115/00
provides short-circuit protection on the Tap-off connector.  
Each tap-off connector can accommodate up to a maximum of 2.5 PCF including  a DCN units 
extension cable; for example: 
Table-top units
- 2 x Concentus Delegate, Chairman units or Interpreter Desks
Flush mounted units
-1 x Dual Audio Interface unit
or 1 x Multi-purpose connection unit
or 5 x Channel selector units.
NOTE: 
 The Tap-off connector can handle up to 2.5 PCF per outlet (1x Concentus unit per tap-off)
FIG 10-5
LBB 4115/00  Tap-off unit limitations
10.3.3  Maximum cable lengths using Trunk-outlets and/or Tap-offs
Extension cables are used to extend the length of cable on DCN system units. The length of cable 
used, directly affects the PCF value of a system.
System limits
 
1. The total cable length (using standard LBB 4116/xx cable) between the CCU and the last unit in 
any branch of the system must not exceed 250 m (820 ft.). This includes all extension cables and 
the 2 m (6.5 ft.) cable attached to each system unit.
2. The total length of the cable from the CCU to the first regenerative tap-off (i.e. from Trunk Cable 
Splitter LBB 4114/00, Audio Media Interface Unit LBB 3508/00 or Extension Power Supply Unit 
LBB 4106/00 must not exceed 100 m (328 ft.).
3. The total length of the cable between regenerative tap-offs outputs must not exceed 100 m     
(328 ft.).
FIG 10-6
Maximum cable lengths
Termination plug LBB 4118/00
(for use with Channel selector panels LBB 3524/10 and LBB 3526/10)
LBB 4115/00
Trunk-line
Trunk-line
Tap-offs
see Note
Trunk-line
Trunk-line
LBB 4115/00
Tap-offs
Port 1
Rec.
Line
In
Out
In
Out
Symmetrical
Trunk
115 V-T4A  230 V -T2A
Tap-off outlet 
Tap-off outlet 
Trunk outlet 
Max. cable length = <100 m (328 ft.) 
Max. cable length = <100 m (328 ft.) 
Max. cable length = <50 m (164 ft.) 
Tap-off outlet 
Max. cable
length =
< 100 m
(328 ft.) 
Max. cable
length =
< 100 m
(328 ft.) 
Trunk-line 
LBB 3500/xx 
Regenerative
tap-off
LBB 4114
LBB 3508
LBB 4106 
Regenerative
tap-off
LBB 4114
LBB 3508
LBB 4106