Calculating the PCF of a System with respect to cable length
10.4.3  Graph reference examples
 in combination with the PCF graph
 
 gives examples of how to calculate the 
PCF value of a single trunk-outlet. Using these examples, the total PCF value of all three trunk-outlets 
of a CCU can be calculated.
TS
=
Trunk-splitter
DA1 = Dual Audio Interface units
TT
=
Table-top discussion units
MPC = Multi-purpose Connection units
CON = Concentus 
units
NOTE: 
 (1 m = 39.37 in)
FIG 10-12 PCF Calculation examples for a single trunk-line
1
50 x 2 m = 100 m
TS
TT
50
TT
59
TT
49
TT
34
1
TS
TT
TT
1
40
DAI DAI
40 x 2 m = 80 m
1
30
MPC
CON
CON
CON
CON
MPC
1
DAI
22
DAI
30 x 2 m = 60 m
34 x 2 m = 68 m
100 m
Ext. cable
TS
22 x 2 m =44 m
100 m
100 m
Ext. cable
Ext. cable
17
MPC
1
MPC
TS
17 x 2 m = 34 m
PCF CALCULATION
BLOCK DIAGRAMS
GRAPH REFERENCE
TT = 59 x 1 PCF =  59 PCF
TS =   1 x 1 PCF =   1 PCF
TOTAL = 60 PCF
DAI = 40 x 1.5 PCF =  60 PCF
TOTAL = 60 PCF
TT = 34 x 1 PCF =       34 PCF
TS =   1 x 1 PCF =         1 PCF
  
TOTAL = 35 PCF
+ Ext. cable          =      60 PCF
DAI = 22 x 1.5 PCF =   33 PCF
TS =        1 x 1 PCF =    1 PCF
  
TOTAL = 34 PCF
+ Ext. cable =               60 PCF
MPC = 17 x 2 PCF =  34 PCF
TS =         1 x 1 PCF =   1 PCF
  
TOTAL = 35 PCF =  
+ Ext. cable =               60 PCF  
MPCU = 30 x 2 PCF =  60 PCF
TOTAL = 60 PCF
Y axis
X axis (max.)
PCF
Ext. Cable (m)
60
0
60
0
60
0
1
24
24 x 2 m = 48 m
CON = 24 x 2.5 PCF =  60 PCF
TOTAL = 60 PCF
60
0
35
100
35
100
35
100
Tap-off
Tap-off
Tap-off
Tap-off
100 m
Ext. cable
13
1
TS
13 x 2 m = 26 m
CON =13 x 2.5 PCF = 32.5 PCF
TS =         1 x 1 PCF =    1    PCF
  
TOTAL = 33.5 PCF =  
+ Ext. cable =               60 PCF  
35
100
Tap-off
9 x 2 m = 18 m