Bosch Appliances Webcam 3922 988 43318 User Manual

Page of 172
  2
Bosch Security Systems | 04-2003 | 3922 988 43318 en
Digital Congress Network | Installation  and Operating Manual | Chapter 10 - Installation Techniques
en | 10-18
Interconnecting Interpretation Equipment
10.10  Interconnecting Interpretation Equipment
A maximum of six desks can be installed per interpreter booth. The desk can be used stand-alone or 
as part of a more comprehensive system.).
NOTE: 
 The maximum number of channels available in a PC based system is 15. However 
when using 15 interpretations, it is recommended to use two CCU’s, one for contribution 
and one for interpretation.  The maximum number of channels available in a system where 
one CCU is used for both contribution and interpretation is 11.
10.10.1  Interconnecting Interpreter desks
The interpreter desk, includes the same interconnection facilities as the delegate and chairman units 
.
 Interpreter desks can be connected in series using the loop-through cabling method, or 
to a Tap-off Unit LBB 4115/00.  When using the Tap-off unit LBB 4115/00, two interpreter desks - one 
to each tap-off connector only - can be connected to the trunk-line cabling, 
10.10.2  Interconnection between booths
shows a typical system using either Trunk-splitter LBB 4114/00 or Tap-off unit LBB 4115/00. 
Using the examples, interpreter desks can be arranged in booths at specific locations where needed. 
Using the Trunk-splitter method a multiple of units in series are connected to a single Trunk-splitter.  
Using the Tap-off unit LBB 4115/00, only ONE desks can be connected to a single tap-off, allowing in 
total only TWO interpreter desks to be connected. In the event of a unit failure, other desks 
connected to the same line can be affected.  Using the Tap-off unit, only one booth is affected, 
however using the Trunk-splitter all units connected to a single line can be affected.
FIG 10-23 Interpreter desk interconnection details
FIG 10-24 Interpretation system layout using trunk-cable splitters and tap-off units
From next unit
To previous unit
BOOTH No.1
BOOTH No.2
. . .
. . .
. . .
To CCU 
LBB 4114/00 
Booths
1 - 7 
Booth 1 
Booth 2 
Booth 7 
Booth 8 
Booth 9 
Booth 15 
Desk 1 
Desk 2 
Desk 2 
To CCU 
LBB 4115/00 
LBB 4115/00 
LBB 4115/00 
Desk 1 
Desk 2 
Desk 1 
Booth 1 
Booth 2 
Booth 3 
Booths
8 - 15