Bosch Appliances Webcam 3922 988 43318 User Manual

Page of 172
  2
Bosch Security Systems | 04-2003 | 3922 988 43318 en
Digital Congress Network | Installation  and Operating Manual | Chapter 4 - Central Control Equipment
en | 4-7
CCU Trunk Communication Board (TCB4)
4.5.2  S9  DIP-Switch settings
 for location, and 
 for functionality of the DIP-switches.
4.5.3  Jumper settings
 for location, and 
 for functionality of the jumpers.
Table 4-3:  S9 DIP-switch settings
TCB4
SW 1
ON*
OFF
Chairman priority  tone ON (default).
Chairman priority  tone OFF
SW 2
ON
OFF*
Audio ‘Mix-Minus’ mode activated in combination with SW3 = OFF
Normal Operation (default).
SW 3
ON
OFF*
Audio ‘Insertion’ mode activated in combination with SW2 = OFF
Normal Operation (default).
SW 4
OFF*
ON
Floor distribution ON (default).
No floor distribution on unused language channels
SW 5
OFF
Reserved (IMPORTANT: must not be changed)
SW 6
ON
OFF*
Active microphones and request will be permanently switched off if 
the priority function of the chairman unit is used. (default).
Active microphones will be  switched off  temporarily if the priority 
function of the chairman unit is activated.
SW 7
OFF
Reserved (IMPORTANT: must not be changed)
SW 8
ON
OFF*
Switching on the CCU will activate the BOOT software, this makes a 
new download possible. All memory settings will be erased and 
returns to the default settings. The unit addresses will not be erased.
Normal operation (default).
* = default setting
DIP switch S9 (default settings) 
For location
 
see
 FIG. 4-3 
and
 FIG 4-5
.
S9
ON
1 2 3 4 5 6 7 8
switches 5 and 7 are ‘RESERVED’
Must NOT be changed
 
Table 4-4: Jumper settings
Jumper
Default
Function
3
X13
1 & 2
Jumpered to provide SRAM Battery back-up
Open when removing back-up battery. (Position 2 & 3)
7
X14
1 & 2
Watchdog active