Bosch Appliances Webcam 3922 988 43318 User Manual

Page of 172
  2
Bosch Security Systems | 04-2003 | 3922 988 43318 en
Digital Congress Network | Installation  and Operating Manual | Chapter 5 - Control using PC
en | 5-9
PC NETWORK SYSTEM
5.6   PC NETWORK SYSTEM
The example below show a typical PC network installation providing more operator control 
positions.  For more information refer to the software manual supplied with the System Installation 
software  LBB 3585.  A typical example of a PC Network system is given in 
FIG 5-8   PC Network system
5.7   Software configuration Master CCU PC (OS/2)          
(Serial Ports 1 and 2)
In the CCU_CFG file ,  three items are reserved to control the serial COM-ports (Port 1 and Port 2) 
on the Master CCU (OS/2 PC) - 
SERIALPORT’
 , 
SERIALSPEED
’ and 
‘SERIALPROTOCOL
 . Both ports can be used to connect a control PC, Remote Controller,  
Allegiant video switcher or other peripheral equipment to the Multi-CCU.
1
2
3
4
5
6
7
8
9
DCD
RD
TD
DTR
GND
DSR
RTS
CTS
RI
1
2
3
4
5
6
7
8
9
DCD
RD
TD
DTR
GND
DSR
RTS
CTS
RI
RS232
RS232
COM2
COM1
ETHERNET CARD
RS232
RS232
CLIENT PC
SERVER PC
Port 1
Port 2
Rec.
Line
In
Out
In
Out
Symmetrical
Trunk
115 V-T4A  230 V -T2A
CLIENT PC requirements:
- Windows 95, 98, NT 4.0 or 2000
- Start-up software LBB 3590.
- DCN software application modules 
as required.
SERVER PC requirements:
- Windows 95, 98, NT 4.0 or 2000
- Start-up software LBB 3590.
- System installation LBB 3585
- DCN software application modules 
as required.
Male
Male
Male
Female
CCU
PC
‘wire-to-wire’
9-pole D-type cable connections
Ethernet  link
(3Com recommended)
4 CLIENT PC’s offer full DCN functionality.              
Up to 8 PC’s offer limited DCN functionality.
COM 1
COM 2
see EXAMPLE 1: Single CCU system
Ethernet
See 
. Installation techniques
Table 5-4: Port number setting
SERIALPORT<number> <portnumber>
number
1
 or 
2
First or second logic port
portnumber
0
1
 - 
2
Turns off serial communication (default when NOT found or invalid port 
given.
Serial port number of the Master CCU PC (OS/2) (COM1 - COM2)
Table 5-5: Port baud-rate setting
SERIALSPEED<number> <baudrate>
number
1
 or 
2
First or second logic port
baudrate
19200
Valid values are: 
9600
19200
57600
 and 
115200
Any invalid value will be decreased to the nearest valid value. Values below 
9600 are set to 9600.
NOTE: 
Baudrate 
115200
 is NOT supported on older PC’s by OS/2.
Table 5-6: Port Protocol setting
SERIALPROTOCOL<number> <type>
number
1
 or 
2
First or second logic port
type
TERMINAL
The serial port is used with an ASCII interface (e.g. terminal for ‘Test’ 
and ‘Diagnostics’ on the CCU).
SIMPLE
The serial port is used with the ‘SIMPLE’ feature protocol.  
FULL
The serial port is used with the ‘FULL’ feature protocol.  
CAMERA