D1255RB/D1256RB/D1257RB | Installation Instructions | 5.0  Specifications 
 
Bosch Security Systems, Inc. | 8/06 | F01U011791B 
13 
 
 
 
Ensure that CF 128 through CF 131, and 
any other functions you are using in the 
menu, are programmed E (enabled), not P 
(passcode required). Refer to Figure 19
 
Figure 19:  Custom Functions 
 
Keypad Funct
ions 
Custom Functions 
E/P* 
128 
Custom Function 128 
129 
Custom Function 129 
130 
Custom Function 130 
131 
Custom Function 131 
132 
Custom Function 132** 
 
133 
Custom Function 133** 
 
134 
Custom Function 134** 
 
135 
Custom Function 135** 
 
136 
Custom Function 136** 
 
137 
Custom Function 137** 
 
138 
Custom Function 138** 
 
139 
Custom Function 139** 
 
140 
Custom Function 140** 
 
141 
Custom Function 141** 
 
142 
Custom Function 142** 
 
143 
Custom Function 143** 
 
 
 
 
5.0 Specifications 
Table 4: 
Specifications for the D1255RB and D1256RB Keypads and the D1257RB Annunciator 
 
Power 
Nominal 12 VDC supplied by the control panel 
Idle:  
104 mA 
Current Required 
Maximum: 
225 mA, with annunciator lit, all 4 Status LEDs on, and warning tone on 
4-wire supplies Data In, Data Out, + 12 VDC, and Common. 
Wiring 
Maximum data loop resistance is 10 
Ω
Base (HxW): 
4.6 in. x 8.2 in. (11.6 cm x 20.7 cm) 
Dimensions (H x W x D) 
Cover :   
4.3 in. x 8.12 in. x 0.8 in. (10.9 cm x 20.6 cm x 2.9 cm) 
Color 
Red 
Display 
16-character vacuum fluorescent display (VSD). 
Each character is a 14-segment unit.  
Operating Temperature 
+32
°
F to +122
°
F (0
°
 C to +15
°
 C) 
Relative Humidity 
5% to 85% at +86
°
F (+30
°
 C)