Security Escort | Technical Reference Manual | 2.0  Setting Up The 
System 
EN | 13 
 
 
Bosch Security Systems | 6/12 | 38947D 
 
2.0 Setting Up The System 
2.1  Initial System Configuration 
The default password is PPP. The 
default password, the Master password, 
and passwords for all system operators 
added by referring to the Operators 
Database in the Security Escort 
Operations Manual
 should be changed. 
 
To generate the map file for the 
screen display, refer to Section 5.1 
Map File Generation and Scaling
.
 
 
To setup the transponder COMM ports 
refer to the Section 3.3.18  
Transponder Comm Port Setup 
Screen.
 
 
To setup the system COMM ports refer 
to the Section 3.3.19  Remote Comm 
Port Setup 
Screen.
 
 
To set the function of the system 
COMM ports and setup remote access, 
see Section 3.3.20  Remote Setup 
Screen.
 
 
To program the system configuration, 
see Section 3.1.6 Transponder 
Database
.
 
 
To program the system responses to 
an alarm, see Section 3.2.3 Security 
Preferences Screen
.
 
 
To program the system responses to 
troubles, see Section 3.3.3 Popup 
Trouble Filter
.
 
 
After communications to the 
transponders are established for any 
transponder that uses a Proxim Radio 
to communicate, program the Uses 
Proxim Radio
 field in the 
Transponder Parameter Change Screen. 
If all alarms are to be silent, 
program the Run Silent field. (See 
Section 3.3.11  Transponder 
Parameter Change 
Screen.)
 
 
If this system has master and slave 
computers, set the Default Master 
Computer and Default Slave Computer. 
(See Section 3.3.20  Remote Setup 
Screen.)
 
 
If using pager access in this 
system, see Section 3.3.23 Pager 
Setup Screen
.
 
 
If this computer runs other programs 
at the same time, Security Escort is 
running, set the Not Always Top 
Window
 field (see Section 3.2.3 
Security Preferences Screen
).
 
 
To program the ID Receiver to 
automatically enter the transmitter 
IDs, see Section 3.2.3 Security 
Preferences Screen
.
 
 
To set the names of the subscriber 
classes, see System Default Screen 
in the Security Escort Operations 
Manual
 
To program the transmitters into the 
Subscriber Database, refer to the 
Security Escort Operations Manual
3.0 System Menus and 
Screens 
3.1  File Menu 
Figure 4: 
File Menu 
 
3.1.1 Locate Transmitters 
This selection allows the operator to 
display the last reported location of 
the transmitter assigned to the 
indicated individual or asset. When the 
individual or asset is selected from 
the list, the time of the last 
supervision report is shown (or None is 
displayed if no supervision report was 
received from that transmitter). On the 
map, the last report location is shown.