No Password Timeout 
If checked, the software does not ask 
for a password after the screen saver 
has run. Normally, this box is not 
checked. 
Bring to Front on Alarm 
If checked, the software jumps to the 
front when a new alarm occurs. 
Normally, this box is checked. 
Bring to Front on Trouble 
If checked, the software jumps to the 
front when a Trouble Screen pops-up. 
Normally, this box is checked. 
Control Room Output to Siren 
If checked, any time there is an 
unacknowledged alarm, the siren output 
on the Control Room Output indicated 
operates. 
Control Room Output to Strobe 
If checked, any time there is an 
unacknowledged alarm, the strobe output 
on the Control Room Output indicated 
operates. 
Control Room Output to Spare 
If checked, any time there is an 
unacknowledged alarm, the spare output 
on the Control Room Output operates. 
Not Always Top Window 
If the Security Escort System is 
intended to be the only application 
running on this computer, leave this 
checkbox unchecked. This prevents other 
applications from taking over the 
screen. Security Escort System is 
always present. If Security Escort 
System is to be run on a computer with 
other applications, check this box and 
Security Escort System shares the 
computer’s display like all other 
Windows applications. After checking 
this box, stop and restart the Security 
Escort System for this feature to take 
effect. This checkbox is unchecked by 
default. 
Excel Test History Files 
Do not check this box in a live 
Security Escort System.
 It is for 
diagnostic engineering testing only. 
Optional Parameter 
These parameters are not currently used 
in the system. Leave unchecked. 
ID Receiver - Assigning a Receiver For 
Automated Transmitter Exchanges 
The Security Escort System contains a 
feature where the transmitter 
identification number of a transmitter 
can be automatically entered into the 
Subscriber Database. This is used for 
entering transmitters when first 
issuing them to subscribers and for 
transmitter exchanges. 
This automatic capture of the 
Transmitter Identification Number is 
accomplished by performing certain 
procedural steps (See the Security 
Escort Operators Manual
) and then using 
the transmitter to make a test 
transmission in close proximity to a 
designated receiver, usually located 
close to the central console. By 
capturing the Transmitter 
Identification Number in this manner, 
keystroke errors are avoided during 
database entries and changes. The 
receiver chosen for this purpose is 
designated as the ID capture receiver. 
To assign the ID capture receiver, its 
transponder name and its point number 
are selected using the two boxes 
labeled transponder and point in the 
middle of the Set System Preferences 
Screen. 
Control Room 
The Security Escort System can activate 
an output to call attention when there 
is an alarm that was received and no 
operator responded to the system yet. 
To assign the control room output, 
select the Transponder Name it is 
connected to and its point number. 
Alarm Zone 
Four alarm zones allow the selection of 
which alarms from specific transmitters 
are reported on this workstation. This 
workstation displays the alarms only 
for the alarm zones that are checked. 
Each transmitter can be assigned to one 
or more alarm zones and when that 
transmitter generates an alarm (if this 
workstation has one or more of the same 
alarm zones checked), that alarm is 
displayed. The system defaults to all 
alarms displayed on all workstations. 
Map Scale %’ 
This value changes the scale the maps 
are presented with. It is not intended 
for normal operations but is typically 
used for testing to allow more of the 
map to be seen. The setting may range 
from 30% to 400%. The Enable Algorithm 
Tweaks