5.3
Day/Night switching
The camera is equipped with a motorized IR filter. The 
mechanical IR filter can be removed in low-light or IR 
illuminated applications by software configuration settings.
If Auto switching mode is selected, the camera automatically 
switches the filter depending on the observed light level. The 
switching level is programmable. In Auto switching mode the 
camera prioritizes motion (the camera gives sharp images 
without motion blur as long as the light level permits) or color 
(the camera gives color pictures as long as the light level 
permits). The camera recognizes IR illuminated scenes to 
prevent unwanted switching to color mode. 
There are four different methods of controlling the IR filter:
via Bilinx communication, 
automatically, based on the observed light levels, or
as part of the programmable mode profile.
5.4
Camera control communication (Bilinx)
This camera is equipped with a coaxial communications 
transceiver (also referred to as Bilinx). In combination with VP-
CFGSFT, the camera setting can be changed from any point 
along the coaxial cable. All menus can be accessed remotely 
giving full control of the camera. With this method of 
communication it is also possible to disable the local keys on 
the camera.To avoid loss of communication on an installed 
camera, the Communication On/Off selection is not available 
while using remote control. This function can only be accessed 
with the camera buttons. Bilinx communications can only be 
disabled using the buttons on the camera.
Disabled camera buttons
When the Bilinx communications link is active, the buttons on 
the camera are disabled.