Bosch Appliances Network Router D6100 User Manual

Page of 168
Conettix D6600/D6100 | Computer Interface Manual | Appendix E: Pulse Output 
 
Bosch Security Systems, Inc. | 1/07 | 4998122703-01 
141 
 
Appendix E: Pulse Output 
 
 
Table 97 to Table 105 (on page 145) vary 
depending on the account number 
specified and the digit parameter 
programmed using the drop-down menus 
in Menu Item 3.1.7 Event 3/1 or 4/1 
(Figure 25). 
 
The output of the receiver depends on the reporting 
digit. Use the settings in Figure 25 that can be changed 
by the user: 
 
Reporting digits 0 to 9 and A are alarms 
 
Reporting digit B is an opening  
 
Reporting digit C is a closing 
 
Reporting digit D is a cancel 
 
Reporting digit E is a restore 
 
Figure 25:  D6200 Receiver Software Line Card 
Configuration 
 
Table 97: 
Pulse 3/1 Format 
 
# Event 
Account 
Number 
Reporting 
Digit 
Device/Mode Displays 
1.
 
ALARM 
123 
Printer: 
D6500 Mode: 
SIA Mode: 
DD/DD TT:TT L01 ACCT  123 ALARM_ZN 4 
[10]1011sssssss123sAsss4[13] 
[10]602415[9]00030101[#s123|NBA4][13] 
2.
 
OPENING 123 
Printer: 
D6500 Mode: 
SIA Mode: 
DD/DD TT:TT L01 ACCT  123 OPENING 
[10]1011sssssss123sOssss[13] 
[10]AA4214[9]00040101[#s123|NOP][13] 
3.
 
CLOSING 
123 
Printer: 
D6500 Mode: 
SIA Mode: 
DD/DD TT:TT L01 ACCT  123 CLOSING 
[10]1011sssssss123sCssss[13] 
[10]F94B14[9]00050101[#s123|NCL][13] 
4.
 
CANCEL 123 
Printer: 
D6500 Mode: 
SIA Mode: 
DD/DD TT:TT L01 ACCT  123 CANCEL 
[10]1011sssssss123s\ssss[13] 
[10]FBCE14[9]00060101[#s123|NOC][13] 
5.
 
RESTORE 
123 
Printer: 
D6500 Mode: 
SIA Mode: 
DD/DD TT:TT L01 ACCT  123 RESTORE 
[10]1011sssssss123sRssss[13] 
[10]FC2214[9]00070101[#s123|NUR][13] 
6.
 
TROUBLE 123 
Printer: 
D6500 Mode: 
SIA Mode: 
DD/DD TT:TT L01 ACCT  123 TROUBLE 
[10]1011sssssss123sTssss[13] 
[10]ACD414[9]00080101[#s123|NBT][13]