Bosch Appliances Network Router D6100 User Manual

Page of 168
Conettix D6600/D6100 | Computer Interface Manual | 3.0  
Computer Communication Protocols 
 
 
16 
Bosch Security Systems, Inc. | 1/07 | 4998122703-01 
 
Table 16: 
Link Test (Message Type 1) Byte Description 
 
# Title 
Description 
Header Character (
h
Optional. Check with the computer automation software for compatibility. 
2 Message 
Type 
3-4 
Receiver Number 
Receiver gateway number from 01 to 99.  
5 Line 
Number 
Line number as zero for link test.  
6-15 
Spaces 
Eleven spaces.  
16-17 Event 
Code 
Event code is @ for link test.  
18-21 
Spaces 
Four spaces.  
22 Trailer 
Character 
Typically, this is HEX 14.  
 
3.1.15  Robofon (Message Type j)  
D6500 Byte Description 
10  11  12  13  14  15  16  17  18  19  20  21  22 
Robofon 
Example 
h j r r l s s s s a a a a a a E E s s s s t 
 
Table 17: 
Robofon (Message Type j) Byte Description 
 
# Title 
Description 
Header Character (
h
)   
Optional. Check with the computer automation software for compatibility. 
Message Type    
3-4 
Receiver Number    
Receiver gateway number from 01 to 99.  
5 Line/Group 
Number 
 
Line number in the receiver gateway that sent the message.   
6-9 
Spaces 
Four spaces.  
10-15 
Account Number 
Six digit account number.   
16-17 
EE 
Event code.  
18-21 
Spaces 
Four spaces.  
22 
Trailer Character 
Typically, this is HEX 14.