Conettix C900V2 | Installation Guide | 3.0  
Setup 
 
 
12 
Bosch Security Systems, Inc. | 8/08 | F01U087780-01
 
3.4 Fallback 
Mode 
In fallback operation, the C900V2 connects the 
PSTN directly to the dialer, bypassing itself from 
the phone circuit. Intercept Mode is maintained 
only if the C900V2 processor operates and there 
are no errors. Fallback Mode is ensured if a CPU 
lockup occurs. 
3.5 Dialer 
Interaction 
Table 8 shows the conditions causing the C900V2 
to change to Fallback Mode. The C900V2 returns 
to Intercept Mode only when all conditions in the 
Intercept Mode Restored column are met. 
 
Table 8: 
Dialer Interaction Forcing C900V2 into Fallback Mode 
 
Condition 
Fallback Mode Occurs 
Intercept Mode Restored 
CPU fails 
Immediately 
C900V2 restart 
Receiver fails 
Immediately 
Link restored 
Receiver does not respond 
to last message 
Dialer goes off-hook (disconnected) 
Link restored 
Intercept Disable Command 
On receipt of the command 
Intercept Enable command 
Intercept Error 
If Fallback after intercept error is enabled, the 
dialer goes off-hook within two minutes of the 
error 
After two minutes 
Switch to Fallback command  On receipt 
One hour or at receipt of Intercept 
Enable command