Bosch Appliances Network Card C900V2 User Manual

Page of 28
Conettix C900V2 | Installation Guide | 3.0   Setup 
 
Bosch Security Systems, Inc. | 8/08 | F01U087780-01 
9
 
Table 4: 
Digital Dialer Protocol (DIP Switches 1 through 4, and 10) 
 
DIP Switches 
10 
1 2 3 4 
Dialer Format of Host Alarm Panel 
ON 
OFF 
OFF 
OFF 
OFF 
Radionics Modem IIe and Modem IIIa
2
 
ON  OFF OFF OFF ON  Radionics 
Modem 
II 
ON 
OFF 
OFF 
ON 
OFF 
DTMF* 
ON 
OFF 
OFF 
ON 
ON 
DTMF* (where dialer retransmits quickly)  
ON 
OFF 
ON 
OFF 
OFF 
BFSK (2300Hz ACK Tone) 
ON 
OFF 
ON 
OFF 
ON 
BFSK (1400Hz ACK Tone) 
ON 
OFF 
ON 
ON 
OFF 
FBI Superfast DTMF (2300 Hz ACK Tone) † 
ON OFF ON ON ON FBI 
Superfast DTMF (1400 Hz ACK Tone) † 
ON 
ON 
OFF 
OFF 
OFF 
Pulse 3/1, 3/1 Checksum (2300 Hz ACK Tone) 
ON  ON  OFF OFF ON  Pulse 
3/1, 
3/1 Checksum (1400 Hz ACK Tone) 
ON 
ON 
OFF 
ON 
OFF 
Pulse 4/2 (Long 2300 Hz ACK Tone) 
ON 
ON 
OFF 
ON 
ON 
Pulse 4/2 (Long 1400 Hz ACK Tone) 
ON 
ON 
ON 
OFF 
OFF 
SIA Bell 103 (110/300 baud, 2016 Hz ACK Tone) 
ON ON ON OFF ON Reserved 
ON 
ON 
ON 
ON 
OFF 
ADT-SIA† 
ON ON ON ON ON Reserved 
OFF  OFF 
OFF 
OFF 
OFF 
Reserved 
OFF OFF OFF OFF ON  Reserved 
OFF  OFF 
OFF 
ON 
OFF 
Scancom 481, 581, 681 †, ‡ 
OFF OFF OFF ON  ON  Reserved 
OFF  OFF 
ON 
OFF 
OFF 
Reserved 
OFF OFF ON  OFF ON  Reserved 
OFF  OFF 
ON 
ON 
OFF 
Telim † 
OFF 
OFF ON ON ON Robofon 
† 
OFF  ON 
OFF 
OFF 
OFF 
Reserved 
OFF ON  OFF OFF ON  Reserved 
OFF  ON 
OFF 
ON 
OFF 
Reserved 
OFF 
ON OFF ON ON Reserved 
OFF  ON 
ON 
OFF 
OFF 
SIA Bell 103 (110/300 baud, 2083 Hz ACK Tone) † 
OFF 
ON ON OFF ON SIA 
V.21 (110/300 baud) † 
OFF  ON 
ON 
ON 
OFF 
Seriee DTMF † 
OFF 
ON ON ON ON Seriee 
FSK 
† 
*  DTMF includes Contact ID, High Speed and 4/2 Express 
†  These formats have not been approved for UL 1610. 