Installation
English 10
From cooktop to materials above: There must be a minimum clearance of 30 
inches between the top of the cooking surface and the bottom of an unprotected 
wood or metal cabinet. See Figure 7: Cabinet Preparation.
24 inches is acceptable when the bottom of the wood or metal cabinet is protected 
by (a) not less than 1/4" of flame retardant material which must be covered with 
(b) not less than No. 28 MSG sheet metal, 0.015 inch stainless steel’ or 0.024 inch 
aluminum or copper. 
From range walls to adjacent materials: See Figure 7: Cabinet Preparation. No 
clearance is required from unit walls to adjacent vertical combustible walls on 
rear, right or left.
Clearance from range top to adjacent vertical walls must be at least 4”.
Prepare Walls and Floor
Seal any holes in the walls or floor. Remove any obstructions (extra electrical or 
gas connections, etc.) so that range will rest against wall properly.
Countertop Requirements
Countertops must be smooth and level.
Mounting Requirements
Install Anti-Tip Bracket
1. Measure to locate bracket position as shown in See Figure 8: Anti-Tip 
2. Secure bracket with 2 screws adequate for mounting surface (i.e., for wood 
floor use wood screws, for concrete floor use concrete anchors and screws).
Ventilation Recommendations
We strongly recommend the installation of a ventilation hood above this 
appliance. For most kitchens a certified hood rating of not less than 300 CFM is 
recommended. The range hood must be installed according to instructions 
furnished with the hood.
Note:
Some cabinet finishes cannot survive the temperatures allowed by 
safety standards, particularly self-cleaning ovens; the cabinets may 
discolor or stain. This is most noticeable with laminated cabinets.
 Figure 8: Anti-Tip Bracket
flush against 
cabinet wall
floor
cabinet wall
rear wall
anti-tippin g
device
 1 9/16" (39.7 mm)
from rear wall to center of screw hole