Bosch Dual-Fuel Slide-In Range User Manual

Page of 80
Installation
English 13
.
Four Wire Range Cord Connection 
(Recommended Method)
1. Disconnect electrical power at breaker box.
2. Remove the terminal block cover to expose the terminal block.
WARNING:
Risk of Electric Shock or Fire. Frame grounded to neutral through a 
ground strap. Grounding through the neutral conductor is prohibited 
for new branch-circuit installations (1996 NEC), mobile homes, and 
recreational vehicles, or in an area where local codes prohibit 
grounding through the neutral conductor. 
For installations where grounding through the neutral conductor is 
prohibited, (a) disconnect the link from the neutral, (b) use grounding 
terminal or lead to ground unit, (c) connect neutral terminal to lead 
branch circuit neutral in usual manner (when the appliance is to be 
connected by means of a cord kit, use 4-conductor cord for this 
purpose).
Use only cord kits rated 125/250 volts (minimum), 30 amperes and 
labeled “For Use with Ranges”. Strain relief provided with cord must 
be installed per instructions included with cord.
 Figure 12: Grounding Requirements
WARNING:
To prevent electrical shock, the grounding prong on the range cord 
should not be cut or removed under any circumstances. It must be 
plugged into a matching grounding type receptacle and connected to 
a correctly polarized 240- Volt circuit. If there is any doubt as to 
whether the wall receptacle is properly grounded, have it checked by 
a qualified electrician.
 Figure 13: 4 Wire Connection