Bosch Appliances Home Security System THE DCN User Manual

Page of 31
SC & SI Remote Interface Description 
en | 10 
 
Bosch Security Systems B.V. | 2003 December | SC & SI Remote Interface Description 
•  DCNC_UNIT_CHAIRMAN 
•  DCNC_UNIT_DELEGATE_CARD 
•  DCNC_UNIT_INTERPRETER 
•  DCNC_UNIT_DUAL_MIC 
•  DCNC_UNIT_PC 
•  DCNC_UNIT_DATA_COMM 
•  DCNC_UNIT_CCU_CONTROL 
•  DCNC_UNIT_FLUSH_CHAIRMAN 
•  DCNC_UNIT_FLUSH_DELEGATE 
•  DCNC_UNIT_AMBIENT_MIC 
•  DCNC_UNIT_DATA_COMM_RS232 
•  DCNC_UNIT_2000_DELEGATE 
•  DCNC_UNIT_2000_CHAIRMAN 
•  DCNC_UNIT_2000_DELEGATE_CARD 
•  DCNC_UNIT_AUDIO_IO 
•  DCNC_UNIT_DAI_CHAIRMAN 
•  DCNC_UNIT_DISC_DELEGATE 
•  DCNC_UNIT_DISC_CHAIRMAN 
•  DCNC_UNIT_ENTRANCE 
•  DCNC_UNIT_EXIT 
•  DCNC_UNIT_FLUSH_DEL_NODISP 
•  DCNC_UNIT_FLUSH_CHR_NODISP 
 
Note that future unit extensions of the DCN system can 
lead to new unit-type, not presented in this list. 
Error codes returned 
SC_E_NOERROR 
3.7 SC_C_START_DQS 
Purpose 
Indicate the CCU that the remote controller wants to communicate with the delegate database in the CCU. 
When the execution of this remote function is omitted, all other remote database functions have no effect and 
will return the error DQSE_APP_NOT_STARTED. 
Availability 
This function is available in CCU system mode congress. 
Parameter structure for the function 
The function requires the following structure as parameters. 
typedef struct 

 BYTE 
byControlType; 
} DQST_APP_CONTROL; 
where: 
byControlType 
Identify that the remote controller likes to perform actions on the 
database of the CCU. Valid values are: 
•  SC_C_DQS_CONTROL  The remote controller likes to have 
control over the database of the CCU. 
Note that the second start of the application (without a stop) always results in an error. 
Response strcuture from the function 
The function has no response parameters. 
Error codes returned 
DQSE_NOERROR 
DQSE_INCONTROL_OTHER_CHANNEL 
DQSE_INCONTROL_THIS_CHANNEL 
DQSE_ILLEGAL_CONTROL_TYPE 
Related functions 
SC_C_STOP_DQS