Bosch Appliances Home Security System THE DCN User Manual

Page of 31
SC & SI Remote Interface Description 
en | 15 
 
Bosch Security Systems B.V. | 2003 December | SC & SI Remote Interface Description 
4 System 
Configuration 
notifications 
4.1 Introduction 
This chapter defines the set of update notifications concerning SC send by the CCU. 
4.1.1 
Update Notification item explanation 
Each description consists of the following items: 
•  Purpose 
A global description of the purpose of the notification. 
•  Notify structure with this update 
The information passed with the update notification. 
4.1.2 
Unit/user event relations 
In the previous chapter a description is given of each remote function with a summary of update notifications 
being the result of executing that function. However, update notifications are also the results of user actions 
done on the actual units or CCU’s. This section gives unit/user event matrices for the SC application in which 
the possible user events are linked with the corresponding update notification(s) depending on the system 
set-up. For some events also the required remote functions to continue SC monitoring and maintaining are 
given. 
The update notifications themselves are described in the remaining sections of this chapter. The 
recommended functions from the SI group are described in chapter 5. 
UNIT-EVENT MATRIX 
Single CCU System
 (Remote Controller connected as specified in [SRS_INF]) 
Event 
Update Notification 
Continue with remote function 
Switch On CCU 
SC_C_CCU_REBOOT 
SC_C_START_DCN 
Recommended before continuing: 
SC_C_GET_CCU_VERSIONINFO 
SC_C_GET_CCU_CONFIG 
SI_C_START_INSTALL and run 
installation as described in 
example-1 in Appendix Appendix C
 
Connect a unit 
SC_C_CONNECT_UNIT 
Recommended before continuing: 
SI_C_START_INSTALL and run 
installation as described in 
example-2 in Appendix Appendix C 
Disconnect a unit 
SC_C_DISCONNECT_UNIT 
 
 
Multi CCU System
 (Remote Controller connected to the Master as specified in [SRS_INF]) 
Event 
Update Notification 
Continue with remote function 
Switch On a Slave 
CCU, while Master CCU 
is still off 
<None>  
Switch On Master CCU 
SC_C_CCU_REBOOT 
SC_C_START_DCN 
Recommended before continuing: 
SC_C_GET_CCU_VERSIONINFO 
SC_C_GET_CCU_CONFIG 
SI_C_START_INSTALL and run 
installation as described in 
example-1 in Appendix Appendix C
 
Switch On a Slave CCU 
SC_C_CONNECT_SLAVE_CCU 
and a few seconds later for 
every unit connected to that 
Slave CCU separately 
SC_C_CONNECT_UNIT 
Recommended before continuing on 
the unit connect updates: 
SI_C_START_INSTALL and run 
installation as described in 
example-2 in Appendix Appendix C 
Switch Off a Slave 
CCU 
SC_C_DISCONNECT_SLAVE_CCU  
Connect a Unit 
SC_C_CONNECT_UNIT 
Recommended before continuing: 
SI_C_START_INSTALL and run 
installation as described in 
example-2 in Appendix Appendix C 
Disconnect a Unit 
SC_C_DISCONNECT_UNIT