Table 33: 
Point ID Codes 
 
Point ID 
Event Description 
Event Code
Explanation 
Section 
Zones 1 to 8 
Burglary Zone 
130 
Burglary 
14.3.1 
 
Medical Zone 
100 
24-Hour Medical 
14.3.1 
 
Panic Zone 
120 
24-Hour Panic 
14.3.1 
 Hold-Up 
Zone 
122 
24-Hour 
Hold-Up 
14.3.1 
 
Tamper Zone 
137 
24-Hour Tamper 
14.3.1 
 
Burglary Zone 
133 
24-Hour Burglary 
14.3.1 
 
Fire 
110 
24-Hour Fire 
14.3.1 
User Specific 1 to 16 
Open/Close Report 
401 
Opening – User # 
Closing – User # 
15.7 
040 
AC MAINS Fail 
301 
AC Power 
15.15 
031 Low 
Battery  309 
Battery 
Test 
Failure 
15.17 
User Specific 1 to 16 
Codepad Duress  
121 
Duress Alarm 
15.8 
041 Codepad 
Panic 
120 
Panic 
Alarm 
15.9 
046 
Codepad Fire  
110 
Fire Alarm  
15.10 
045 
Codepad Medical 
100 
Medical Alarm 
15.11 
042 
Code Retry Limit Exceeded 
421 
Access Denied 
15.19 
044 
Test Report  
602 
Test Report 
15.21 
047 
Test Report 
602 
Test Report 
18.5
Zone Specific 1 to 8 
Sensor Watch 
307 
Sensor Self Test Failure 
15.3 
Zone Specific 1 to 8 
Trouble 
380 
Sensor Trouble 
15.2 
Zone Specific 1 to 8 
Bypass 
570 
Zone Bypass 
15.1 
00 
AUX Power Supply Fail 
300 
System Trouble 
15.13 
 
 
 
 
 
10.1.2 Point 
ID 
Codes 
Table 33 on page 43 shows the different Point ID 
Codes and Event Codes that are sent to the base 
station receiver when using Contact ID Reporting 
Format. All Event Codes are fixed. The control panel 
always sends the same code because there are no 
programming locations to change the codes. 
10.1.3  4 + 2 Express Reporting Format 
The 4 + 2 Express Format reports a Subscriber ID 
Number followed by an Expansion Code. The 
reporting Channel Number is sent directly after the 
Expansion Code. 
 
Table 34: 
Example Reporting in 4 + 2 Express 
Format 
 
Subscriber ID 
Number 
Expansion 
Code 
Channel 
Number 
SSSS 
C
H
 
 
 
Table 35: 
4 + 2 Express Reporting Format 
 
New Event 
4 + 2 Report 
Alarm 
SSSS AC
H
 
Trouble SSSS 
TC
H
 
Bypass 
SSSS BC
H
 
AC Fail 
SSSS EA
C
 
Low Battery 
SSSS LL
B
 
Opening Report 
SSSS OU 
Closing Report 
SSSS CU 
Test Report 
SSSS T
E
Program Altered 
SSSS P0 
Duress SSSS 
DD
0
 
 
Event 
4 + 2 Report 
Alarm Restore 
SSSS R C
H
 
Trouble Restore 
SSSS TR C
H
 
Bypass Restore 
SSSS B
R
 C
H
 
AC Fail Restore 
SSSS E
R
 A
CR
 
Low Battery 
SSSS L L
B
 
Low Battery Restore
SSSS L
BR