Bosch Appliances Home Security System DX4010I User Manual
DX4010i | Installation Instructions | 6.0 Remote Programming Direct Connection
Bosch Security Systems, Inc. | 1/05 | 4998141106C
9
Table 4: SDI Bus Address DIP Switch Settings
SDI DIP Switch Settings
SDI DIP
Switches
Switches
S1
S2
S3
S4
S5
S6
S7
S8
Module
Address
Address
1 2 4 8
16
32
(Mode)
64
(Option/SDI)
128
(Checksum +1)
80*
ON
ON
ON
ON
OFF
OFF
OFF
OFF
81
OFF ON ON ON
OFF
OFF
OFF
OFF
82
ON
OFF
ON
ON
OFF
OFF
OFF
OFF
83
OFF OFF ON ON OFF
OFF OFF
OFF
84
ON
ON
OFF
ON
OFF
OFF
OFF
OFF
85
OFF ON OFF ON
OFF
OFF
OFF
OFF
86
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
87
OFF OFF OFF ON OFF
OFF OFF
OFF
88**
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
89
OFF ON ON OFF
OFF
OFF
OFF
OFF
8A
ON
OFF
ON
OFF
OFF
OFF
OFF
OFF
8B
OFF OFF ON OFF
OFF
OFF OFF
OFF
8C
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
8D
OFF ON OFF OFF
OFF
OFF
OFF
OFF
8E
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
8F
OFF OFF OFF OFF
OFF
OFF OFF
OFF
Positions 5, 6, and 8 are not used for SDI bus.
* Used for BIS, PC 9000, and other third party applications.
** Used for RPS and alternate communication.
SDI bus control panels (v6.0 or higher): D9412G, D7412G, D7212G, D9124, D9112, D7412, and
D7212.
D7212.