Bosch Appliances Home Security System D9112B User Manual

Page of 96
D9112B | Program Entry Guide | 2.0  Area Wide Parameters 
EN | 32 
 
 
Bosch Security Systems | 2/04 | 74-06145-000-D 
 
A# Restricted O/C 
This item determines if this area can restrict 
Opening
 and 
Closing
 report activity. 
Restricted
 
Opening
 report refers to the panel sending an 
Area
 
Opening
 report ONLY when the area is 
disarmed after a non-fire alarm. 
Restricted
 
Closing
 report refers to the panel sending an 
Area
 
Closing
 report ONLY when the area has been 
master armed with controlled points that were faulted during the arming sequence. The sequence of reports 
generated by a restricted closing are: 
Was
 
Forced
 
Armed
Forced
 
Point
Forced
 
Close
, then 
Closing
 
Report
Default: 
No 
Selection: 
Yes or No 
Yes 
Restrict 
Opening
 and 
Closing
 reports for this area. 
A# Area O/C
 must be programmed YES to 
generate 
Restricted
 
Opening
 and 
Closing
 reports. 
Note: 
If a passcode is not required for arming or disarming and this item is YES, the area only sends 
Restricted 
Opening and Closing reports. In this case, restricted reports are sent without User ID. 
Opening /Closing Window does not affect this report: Windows do not prevent 
Restricted
 
Opening
 and 
Closing
 reports from being sent. Early or late designations are NOT added to 
Opening
/Closing reports when they are sent according to the rules for restricted Opening/Closing 
reports. 
No 
Do not restrict 
Opening
 and 
Closing
 reports for this area. 
Regardless of programming in Authority Levels 
L## Restricted O/C
, reports are not restricted in this 
area when this item is programmed NO.