D9112B | Program Entry Guide | 6.0  Passcode Worksheet 
EN | 67 
 
 
Bosch Security Systems | 2/04 | 74-06145-000-D 
 
User 
Default: 
Selection: 
0 or 1 to 99 
Enter the User number you are programming. 
0101
0101
0101
 
 
User 0 is the Service Authority Level (Level 
15). The Program Record Training Sheet 
shows the functions enabled for Authority 
Level 15. 
You cannot change the programming for 
Authority Level 15 functions. 
The authority level cannot be changed for 
User 0, and no User Access Window can 
be assigned. The passcode number for 
User 0 can only be changed on the 
programmer, or by User 0 from the 
command center. 
As ENTER PASSCODE message displays 
at the command center when User 0 is 
entered in response to the User prompt in 
the DEL PASSCODE command center 
function. Only the Service Authority Level 
(User 0) can delete User 0. When a user 
other than User 0 tries to delete the 
passcode for User 0, the command center 
displays NOT IN USE. 
User 0 cannot be added from the command 
center once it has been deleted. It must be 
re-entered using the programmer. 
U## Passcode 
Default: 
_ _ _ _ _ _ 
Selection: 
Three to six digits ( 0 to 9) 
Enter from three to six digits to enable a primary 
passcode for this User number.  
User ID Code 00 is the Service Authority Level. The 
default passcode for the Service Authority Level is 
123. 
The programmer does not allow you to enter any 
passcode number that could conflict with a 
secondary (duress) passcode. This rule applies even 
if 
Duress 
is disabled. For example, once a passcode 
of 654321 is entered, 654322, 654323, 654320, and 
654329 can not be entered. 
The D9112 generates a 
Usr Code Tamper
 report 
after six consecutive attempts to enter a passcode 
that does not exist in the system. There is no time 
limit for the consecutive attempts, but all attempts 
must be made from the same command center 
address. After a valid passcode is entered, the 
counter resets to zero. Entering a passcode with no 
authority to execute a function does not count as an 
attempt, as long as the passcode is programmed in 
the panel. 
The D9112 operation depends on the D5200 or 
D5300 programmer revision. 
In the D5200 revision 1.4 and the D5300 revision 
2.15, any passcode entered in the Passcode 
Worksheet can turn off bell relays within the scope 
of the command center. This is true even if the 
passcode has no authority level assigned for any 
area. 
In the D5200 revision 1.60 and the D5300 revision 
2.23 (or higher) , a passcode must be programmed 
with an authority level in the area in order to turn 
off bell relays for the area. Even if the authority level 
does not have the authority to perform any 
command center function, if the passcode is assigned 
any authority level for the area, it can be used to 
turn off bell relays in the area. 
U## User Window 
Default: 
Blank 
Selection: 
Blank or 1 to 15 
When a User Window is assigned, the user’s 
passcode is valid during the time programmed for 
the User Window. Program User Window in User 
Access Windows
To enable the user’s passcode all the time, leave this 
item blank. 
To enable the user’s passcode only during specific 
times, enter a User Window number.