Bosch Appliances Home Security System D9412GV2 User Manual

Page of 74
D9412GV2/D7412GV2 | Operation and Installation Guide | 9.0   Off-Board Points 
 
38 
Bosch Security Systems, Inc. | 5/05 | F01U003641B 
 
9.3 
Installing the D8125 POPEX Module 
 
 
For information on the Multiplex Bus 
Interface, refer to the D8125 Multiplex Bus 
Interface Operation and Installation Guide
 
(P/N: 36796). 
Save the POPIT Label Sheets: The D8125 is 
packaged with two sets of POPIT label sheets. One set 
is marked “Bank 1” for use with the D7412GV2 and 
D7212GV2.  The other set is marked “Bank 2” for use 
with the D9412GV2 and D9112. Use the sheets later to 
label the POPITs. Refer to Section 9.3.6 POPIT Module 
Point Assignments
 on page 40.  
9.3.1 Mounting 
To install the D8125 in the enclosure with the control 
panel: 
1.  Align the D8125 POPEX Module with any of the 
four mounting locations in the enclosure  
(Figure 2 on page 15). 
2.  Using the screws provided with the module, secure 
it in the enclosure. 
9.3.2 
Wiring the D8125 to the Control Panel 
To wire one or two D8125 Modules to the control 
panel (Figure 12 on page 36 and Figure 13 on page 37): 
Power Down the Control Panel: Disconnect the 
positive (red) battery lead at the battery and unplug the 
transformer. 
For Points 9 to 127 (9 to 75 on D7412GV2): 
1.
 
Connect the GND terminal of the D8125 to 
Terminal 23 on the D9412GV2 or to Terminal 9 
on the D7412GV2. 
2.  Connect the OUT terminal of the D8125 POPEX 
Module to ZONEX IN 1, Terminal 27.  
3.   Connect the IN terminal of the D8125 POPEX 
Module to ZONEX OUT 1, Terminal 28.  
4.  Connect the AUX terminal of the D8125 to 
Terminal 24 on the D9412GV2 or to Terminal 3 
on the D7412GV2. 
For Points 129 to 247 (D9412GV2 only): 
1.  Connect the GND terminal of the D8125 to 
Terminal 23. 
2.  Connect the OUT terminal of the D8125 POPEX 
Module to ZONEX IN 2, Terminal 25.  
3.   Connect the IN terminal of the D8125 POPEX 
Module to ZONEX OUT 2, Terminal 26.  
4.  Connect the AUX terminal of the D8125 to 
Terminal 24. 
Refer to Section 9.3.4 Wiring Data Expansion Loops to 
POPEX Modules
 on page 39 for instructions on 
connecting POPITs to the D8125 POPEX Module. 
9.3.3 
Wiring POPITs to the Data Expansion Loop 
Use one two-wire data expansion loop or distribute the 
POPITs on up to three loops. Setting DIP switches on 
the POPIT Modules assigns them to point numbers. 
Refer to Section 9.3.6 POPIT Module Point Assignments on 
page 39. 
Review Section 4.6.2 Installing and Wiring Detection 
Devices 
on page 18 to determine if shielded wire is 
required. Determine the wire gauge for the length of 
each data expansion loop using Table 14 
Table 14: 
Data Expansion Loop Wire 
Specifications 
 
Maximum Length of All Data Expansion Loops 
Combined 
AWG 
Length in Meters (Feet) 
22 
548 (1800) 
20 881 
(2890) 
18 
1402 (4600) 
16 2231 
(7320) 
14 
3551 (11,650) 
Combine Data Expansion Loops: The maximum 
lengths shown in Table 14 are for all data expansion 
loops connected to the same POPEX Module 
combined. 
Wiring POPITs Together: Do not connect POPITs to 
each other in series or with a T-tap. Doing so might 
cause random missing POPIT conditions. 
To connect POPITs to one another in parallel: 
1.  Connect the positive (+) data terminal from one 
POPIT to the positive (+) data terminal on the next 
POPIT. 
2.  Connect the negative (-) data terminal from one 
POPIT to the negative (-) data terminal on the next 
POPIT. 
3.  Repeat Steps 1 and 2 to connect all POPITs to the 
expansion loop. It is not necessary to wire the 
POPITs in any particular order on the loop. The 
switch setting on each POPIT assigns it a point 
number, regardless of its physical location. 
 
 
Before installing the POPITs, make sure the 
resistance on the data expansion loop is no 
more than 40 
Ω
Three-inch Clearance for Tampered POPITs: 
Mount tampered POPIT modules at least 7.6 cm (3 in.) 
apart to prevent the tamper magnets from interfering 
with each other.