Bosch Appliances Home Security System D9412GV2 User Manual

Page of 74
D9412GV2/D7412GV2 | Operation and Installation Guide | 9.0  Off-Board Points 
 
Bosch Security Systems, Inc. | 5/05 | F01U003641B 
47 
 
Figure 19:  D8128D OctoPOPIT Sensor Loops 
COM IN OUT+12V P1 COM P2
P3 COM P4
P5 COM P6
P7 COM P8
1
2
3
4
5
 
1 -  D8128D OctoPOPIT 
2 -  To control panel 
3 -  To additional OctoPOPIT sensor loops 
4 -  OctoPOPIT sensor loops 
5 -  1 k
Ω 
EOL resistor (P/N: P105BL, package of 
eight) 
 
9.5 
Testing Off-Board Points 
Use the Service Walk Test to test off-board points. 
Refer to the D9412GV2/D7412GV2/D7212GV2 
Installation and Troubleshooting Quick Reference Guide
 
(P/N: F01U003638) for instructions. Test to ensure that 
all off-board points operate properly.  
Walk Test and Service Walk Test Do Not Show 
Extra Points: If the point assignment switches on a 
POPIT or OctoPOPIT are set incorrectly, missing and 
extra points can occur. If the same point number is 
assigned to two or more POPITs or OctoPOPITs, none 
of the points with that number test correctly. Refer to 
Section 9.1 Point (Zonex) Bus: D9412GV2 Terminals and 
D7412GV2 Terminals 
on page 34.