10.3 
Cycle Door?
 
1. 
To momentarily unlock an access door and allow a person into an 
area, press [ENT] at the Cycle Door? prompt. 
 
The display shows 
CYCLE 1 2 3 4 5 6 7 8
 
if all doors are in 
a normal state and available. If a door is not in a normal state, the 
number of the door is replaced with one of the symbols indicated 
in Table 1. 
 
Table 1: Key to Symbols 
 
 
Symbol Description 
--- 
Door is not active, not in scope, or user does 
not have access level authority 
Door is timed door sequence 
Strike and shunt are latched active (held open) 
Strike and shunt are deactivated (secured) 
There is a problem with the door; call your 
security company 
 
 
2. 
Enter the number of the door to cycle then press [ENT]. This 
door cycles and the display changes to reflect the new status of 
the doors.  For example, to cycle Door 3, at the following prompt: 
 
CYCLE DOOR 1 2 3 4 5 6 7 8
 
 
press [3], then [ENT]. The display shows: 
 
CYCLE DOOR 1 2 C 4 5 6 7 8
 
 This 
indicates that all doors are in a normal state, except for Door 
3, which is cycled. 
3. Press 
[ESC]
 to leave this subfunction, or enter another door 
number to cycle.