Bosch Appliances Home Security System D1265 User Manual

Page of 92
D1265 | Owner's Manual | Part II: System Commands  
 
24 
Bosch Security Systems, Inc. | 9/10 | F01U169130-02
 
If there are no events to view, 
There are 
currently no events in memory
 
shows. 
 
6.  You can return to idle text at any time by 
pressing 
Exit button. 
Walk Test (CMD + 4 + 4) 
Description 
Use this function to test keypads, detection devices, 
and sounders (both interior and exterior) to be certain 
they function properly. You can review untested points 
at your keypad to help pinpoint any problems. 
You cannot arm your system while in the walk test 
mode, and no alarm reports are sent to your security 
company unless a 24-hour point is activated (such as 
fire or panic). A Walk Test Start Report might be 
programmed to be sent to your security company. 
Upon initiation, the walk test tests the burglary bell 
pattern on the bell output and ring the keypad 
burglary bell for 2 sec. The AC is disabled for 4 
minutes in order to test the system’s battery power. If 
the battery cannot maintain the system for the 4-
minute period, the keypad appears to power off. If 
your keypads are programmed to be supervised, the 
main alarm panel piezo intermittently during this 4-
minute period. If this happens, contact your security 
company. At the end of the 4-minute period, AC is 
returned to the system and the control panel restores. 
To test individual detection devices, simply activate 
sensors and open protected doors and windows one-at-
a-time. As each detection device is faulted, the keypad 
emits a brief tone and the display indicates for 60 sec 
that the point has been tested. This verifies that each 
detection device is working properly. 
Using Walk Test 
1.  Ensure the display shows disarmed idle text. 
2.  Press the 
CMD button. The display shows 
*System Command*. 
 
3.  Press the 
4 button and then the 4 button. 
 
If you prefer, you might use the function 
list in place of Steps 2 and 3 to initiate 
this function. 
Press the Menu button to enter the 
function list. 
Press the Next button repeatedly. 
When you reach the Walk Test button, 
press it. 
 
 
4.  The burglary bell sounds for 2 sec. When the 
display shows 
### points remain to be tested 
(### is the number of points) you can begin.  
 
Test each point by first opening and then closing 
the door or window, or activating the other 
detection device types. 
Check the display after testing each point. For 
interior points, walking past the device once is 
sufficient. If any point will not test correctly, 
contact your security company for service. 
5.  During the Walk Test you might want to refer to 
the points that remain untested by pressing the 
View untested pts button. 
The display shows 
### pts untested. 
 
Press the 
Next Pt or Prev Pt
 
buttons to refer to 
information about specific points that have not 
yet been tested.