Bosch Appliances Home Security System D1265 User Manual

Page of 92
D1265 | Owner's Manual | Part IV: Multi-Area Use 
 
 
Bosch Security Systems, Inc. | 9/10 | F01U169130-02 
63
 
4.  The display changes and shows 
Master Arm 
All with the following options: 
  Previous button– scrolls to the last area that 
can be armed (based on passcode and authority 
level) 
  Next button – scrolls to the first area that can 
be armed (based on passcode and authority 
level) 
  Arm button – arms all areas (based on passcode 
and authority level) 
  Exit button – returns the display to idle text 
 
5.  If the 
Next button is pressed, the first area that 
can be armed (based on passcode entered and 
user authority level) is shown (
AREA 1 
WAREHOUSE is used an example of the first 
area that can be armed). 
6.  Pressing the 
Arm button causes AREA 1 
WAREHOUSE is now arming… to display for 
3 sec before the prompt to arm the next 
available area is shown. 
Turning on Multiple Areas with a Passcode 
You can use your personal passcode to turn on both 
perimeter and interior points in all areas where your 
passcode has authority. If there are areas already 
turned on, this function rearms those areas in addition 
to turning on all authorized areas that are currently off. 
1.  Enter your passcode and press 
ENTER. 
 
2.  The keypad shows the following: 
 
Keypad scope and/or your authority level limit 
the actual number of areas you might turn on. 
For example, if you have authority to arm all 
areas but the scope of the keypad you’re using 
is limited to areas 1, 2, and 5, then you only can 
turn on areas 1, 2, and 5. 
3.  If a point is faulted (door or window open for 
example). Refer to Turning On the System 
(Arming) With Doors or Windows Open 
on page 17 
for more information. 
Faulted Points in Other Areas 
If there is a faulted point in an area you select (other 
than the one you are in), 
Check Area 1
 
(1 is used as 
an example here) appears for 3 sec and then the 
display returns to the area disarmed idle text. 
If there is a faulted point in more than one area and 
the system is being armed, the display prompts 
Check 
Area 1 
3
 meaning there are faulted points in Areas 1 
and 3. 
Try one of the following: 
  Clear faulted points (close doors and/or windows) 
and return to step 1. 
  Bypass faulted points (if your system and/or 
authority allows) and return to step 1. 
  Force arm (if your system and/or authority allows). 
Refer to Turning On the System (Arming) With Doors 
or Windows Open 
on page 17 for more information.