Bosch Appliances Home Security System CC880 User Manual

Page of 32
CC880/LP880, SC8016 | Operators Guide | 4.0 
Arming the System 
EN | 8 
 
 
Bosch Security Systems | 6/04 | 920036O.OG.162 
 
4.1 Forced 
Arming 
Forced arming arms the system when a zone is not 
sealed. If the system does not arm and a long beep is 
heard, forced arming is not permitted. In this case, 
you must ensure that all zones are sealed or manually 
isolated before you can arm the system. 
4.2 
Arming in AWAY Mode 
When you leave your premises and require all zones 
to be in a ready state to detect intrusion, you arm the 
system in AWAY Mode.  
There are two different methods for arming the 
system in AWAY Mode. Method one is standard and 
always operates. Method two is optional and can be 
disabled by your installer if you do not want to use 
single button arming. 
Table 9: 
How to Arm the System in AWAY Mode
 
Method One 
Enter your user code followed by the 
[#] button (for example, [2 5 8 0 #]). 
Two beeps are heard and the AWAY 
indicator displays. Exit time starts 
counting. 
Method Two 
Hold down the [#] button until two 
beeps are heard. 
The AWAY indicator displays and 
exit time starts counting. 
4.3 
Arming in STAY Mode 1 
STAY Mode 1 is only used when the perimeter and 
unused areas of the premises need to be armed to 
detect an intruder entering the premises. At the same 
time, this mode allows you to move freely within an 
area that is automatically isolated. 
Only your security company can program zones 
automatically isolated in STAY Mode 1. 
There are two different methods for arming the 
system in STAY Mode 1. Method one is standard 
and always operates. Method two is optional and can 
be disabled by your installer if you do not want to 
use single button arming. 
Entry Guard Timer For STAY Mode 1 
When arming the system in STAY Mode 1, an 
optional entry timer called Entry Guard Timer For 
STAY Mode 1 is used. Use this entry timer to delay 
the sirens if a zone is not automatically isolated and 
triggered an alarm condition. Entry Guard Timer For 
STAY Mode 1 is the delay time used for all zones 
except 24-hr. zones when the system is armed in 
STAY Mode 1 or STAY Mode 2. 
If the Entry Guard Timer For STAY Mode 1 is 
programmed and a zone not automatically isolated is 
triggered, the codepad beeps twice a second until the 
entry timer expires or the system is disarmed. If the 
alarm condition is not reset by entering your user 
code followed by the [#] button (such as, [2 5 8 0 #]) 
before the entry timer expires, the sirens activate into 
alarm. Only your installer can program this feature. 
Table 10:  How to Arm the System in STAY Mode 1 
 
Method One 
Enter your user code followed by the [*] 
button (for example, [2 5 8 0 *]). 
Two beeps are heard and the STAY 
indicator displays. Exit time starts counting. 
Any zones programmed to be automatically 
isolated in STAY Mode 1 flash until exit time 
expires. At the end of exit time, all zones 
selected to be automatically isolated turn off 
and the codepad gives one short beep. 
Method Two 
Hold down the [*] button until two beeps are 
heard. 
The STAY indicator displays and exit time 
starts counting. 
Any zones programmed to be automatically 
isolated in STAY Mode 1 flash until exit time 
expires. At the end of exit time, the zone 
indicators turn off and the codepad gives 
one short beep. 
4.4 
Arming in STAY Mode 2 
STAY Mode 2 is only used when the perimeter and 
unused areas of the premises need to be armed to 
detect an intruder from entering the premises. At the 
same time, this mode allows you to move freely 
within an area that is automatically isolated. Any 
Master Code user can program zones to be 
automatically isolated in STAY Mode 2. 
Entry Guard Timer For STAY Mode 2 
When arming the system in STAY Mode 2, an 
optional entry timer called Entry Guard Timer for 
STAY Mode 2 can be used. Use this entry timer to 
delay the sirens if a zone is not automatically isolated 
and triggered into alarm condition. Entry Guard 
Timer for STAY Mode 2 is the delay time used for 
all zones except 24-hr. zones when the system is 
armed in STAY Mode 1 or STAY Mode 2. 
If the Entry Guard Timer for STAY Mode 2 is 
programmed and a zone, not automatically isolated, 
triggers, the codepad beeps twice a second until the 
entry timer expires or the system disarms. If the 
alarm condition is not reset by entering your user 
code followed by the [#] button (for example,  
[2 5 8 0 #]) before the entry timer expires, the sirens 
activate into alarm. Only your installer can program 
this option.