Bosch Appliances Home Security System D7212G User Manual

Page of 68
D7212G Operation and Installation Guide
Page 16
© 2003 Bosch Security Systems
4998138544C
D7212G
Overview
2.2.1
Compatible Accessories
See the Bosch Security Systems Intrusion Catalog for a complete list.
D122
Dual Battery Harness
D1256
Fire Command Center
D125B
Powered Loop
Interface Module
D1257
Fire Annunciator
D126
12 V, 7 Ah
Rechargeable Battery
D1260
Alpha V Command Center
D127
Reversing Relay
D1640
16.5 VAC 40 VA Transformer
D129
Dual Class A Initiation
Circuit Module
D5200
Programmer
D130
Relay Module
D5500
Remote Account Manager IV
D136
Plug-In Relay
D8004
Transformer Enclosure
D161
Phone Cord
D8121A,
D8122
Derived Channel STU
D162
Phone Cord
D8125
POPEX Module
D185
Reverse Polarity
Module
D8125MUX
Multiplex Bus Interface
D192C/D192G
Bell Circuit
Supervision Module
D125INV*
Wireless Interface Module
D279A
Independent Zone
Control (On-Board
and OctoPOPIT
Points)
D8128D
OctoPOPIT Module
D442
Bells (10 in.)
D8129
OctoRelay Module
D448/D449
Mini-Horns
D8130
Release Module
D720
Command Center
(Area LED)
D9127U/T
POPIT Module
D720R
LED Command
Center (red)
D9131A
Parallel Printer Interface Module
D720W
LED Command
Center (white)
ZX776Z
PIR Motion Sensor (50 ft.) with
POPIT
D1218
12 V, 17.2 Ah
Rechargeable Battery
ZX794Z
PIR Motion Sensor (80 ft.) with
POPIT
D1255
Command Center
(General Purpose)
ZX835
PIR/Microwave Motion Sensor
(35 ft.)
D1255R
Command Center
(red)
Z938Z
PIR Motion Sensor (60 ft.) with
POPIT
D1255W
Command Center
(white)
ZX970
PIR/Microwave Motion Sensor
(70 ft.) with POPIT
* The D8125INV has not been
investigated by UL. Not to be used
in UL Listed installations.
2.3
Features in D7212G
2.3.1
Introduction
The Bosch Security Systems D7212G Control/Communicator provides up to 40 points of protection and supports up to
four separate areas. The panel is armed and disarmed by area, and several areas can be armed and disarmed with one menu
function. The D7212G uses a built-in digital communicator to send reports to the receiver. A maximum of 32 unsupervised
command centers can be connected to the system.
2.3.2
Ground Fault Detect
In order for the D7212G to be able to detect ground fault conditions, the Earth Ground Terminal on the control/
communicators had to be electrically isolated from all other terminals. A Ground Fault Detect Enable switch (S4) has been
added to the panel and is located just under Terminal 10, Earth Ground. For more information on the operation of this
function, see Section 3.5.2 Ground Fault Detect Enable on page 22.