Event message:
Amplifier missing
Originator:
Amplifier channel of a basic amplifier in which the fault 
occurred.
Extra information:
----
Description:
Logs the absence of an amplifier channel (based on 
missing battery and mains power supply).
Resolve:
When the fault disappears or when the unit 
disconnects.
Recommended action:
Check whether both CAT-5 cables between the multi 
channel interface and the basic amplifier channel are 
correctly connected.  
Event message:
Amplifier initialization failure
Originator:
Power amplifier channel in which the fault occurred.
Extra information:
----
Description:
Logs the inability of a power amplifier to return from 
the standby mode.
Resolve:
When the fault disappears or when the power 
amplifier disconnects.
Recommended action:
Switch the power amplifier off and on again.
Event message:
Amplifier overheat
Originator:
Amplifier channel in which the fault occurred.
Extra information:
This fault event cannot be generated by LBB4428/xx 
Power Amplifiers.
Description:
Logs the overheat (> 85 °C) of an amplifier channel. 
The system decreases the audio level with 3 dB. This 
fault event can occur even when the power amplifier is 
disabled with the configuration software.
Resolve:
When the fault disappears or when the power 
amplifier disconnects. If this fault is 
acknowledged/reset, any Redundant Supply 24V in 
the same amplifier channel will also be 
acknowledged/reset. 
Recommended action:
Check if the fans of the power amplifier operate 
correctly. Also check the ambient temperature of the 
rack. If necessary, use forced cooling.
Event message:
Amplifier overheat: (amplifier channel) muted
Originator:
Amplifier channel in which the fault occurred.
Extra information:
This fault event cannot be generated by LBB4428/xx 
Power Amplifiers.
Description:
Logs the overheat (> 90 °C) of an amplifier channel. 
The system mutes all amplifier channels in the power 
amplifier. This fault can occur even when the power 
amplifier is disabled with the configuration software.
Resolve:
When the power amplifier disconnects or when the 
fault is resolved automatically.
Recommended action:
Check if the fans of the power amplifier operate 
correctly. Also check the ambient temperature of the 
rack. If necessary, use forced cooling.