61.8  Linksys SPA3102 configuration
The Praesideo PC Telephone Interface Client connects 
directly to VoIP networks. In case a connection should 
be established to an analog telephone or PBX a 
converter is needed.
Although the Linksys SPA3102 Voice Gateway is 
certainly not the only device that can be used with the 
Praesideo PC Telephone Interface Client to connect to 
analog telephone lines (POTS), this unit is 
recommended for its availability, price and ease of 
configuration. 
This section describes how to configure the Linksys 
SPA3102 for use with the Telephone Interface. It covers 
the device initialization, network configuration, 
connection with the Telephone Interface and disconnect 
detection.
 
61.8.1   Device initialization
To make sure that previous configuration settings do not 
interfere with the flow of this configuration, first perform 
the factory reset procedure. Remove all connectors from 
the device. Connect a telephone to the Phone port. 
Connect the power connector. Dial '****', wait for the 
menu response, dial '73738#', dial '1', hang-up. The 
device will now reset.
61.8.2   Network configuration
The device will now be configured in such a way that 
both configuration and telephone traffic will run 
through the Internet port. This port is also the port used 
to connect to the network containing the PC of the PC 
Telephone Interface Client
.
Connect the PC network adapter of a PC to the 
Ethernet port of the SPA3102. Configure the PC 
network adapter to dynamically acquire an IP address 
(from the SPA3102). This will be in the 192.168.0.x 
range. Once the IP address is acquired, start a web 
browser and open http://192.168.0.1. The SPA3102 
web configuration page opens.
Click 'Admin login' and click 'Advanced'. Make sure 
both modes are active in order to access all 
configuration fields.
Router 
 Wan Setup 
 Internet Connection Settings
Connection Type: Static IP
Router 
 Wan Setup 
 Static IP Settings
Static IP: <WAN IP address> 
NetMask: <Network mask>
Router 
 Wan Setup 
 Remote Management
Enable WAN Web Server: yes
Click 'Submit all changes'
Now, the Ethernet port is no longer required. The web 
configuration is now accessible using the Internet port 
and the WAN IP address.
61.8.3   PSTN configuration
Now the device will be configured to register itself on 
the Telephone Interface server and to forward incoming 
calls from the PSTN port directly to the Telephone 
Interface server. Make sure that 'Admin Login' and 
'Advanced' are active. 
Voice 
 PSTN Line 
 Proxy and registration
Proxy: <Telephone Interface IP address>
Voice 
 PSTN Line 
 Subscriber Information
figure 61.1: Linksys SPA3102 Voice Gateway with 
Router
Note
The combination <WAN IP address> and 
<Network mask> should be provided by the 
network administrator to cover both the Linksys 
unit and the network address of the PC that 
runs the PC Telephone Interface Client.