Detectors and Accessories | Motion PIR | 145
ISM‑BLP1‑P Blue Line
Pet‑Friendly PIR Detector
Features
▶ 11 m x 11 m (35 ft x 35 ft) broad coverage
▶ EN50131-2-2 Grade 2 compliant
▶ Pet Friendly®
▶ First Step Processing (FSP)
▶ Flexible mounting height from 2.3 m to 2.7 m (7.5 ft to
9 ft)
▶ No range or height adjustments required
▶ Installation-friendly two-piece design
▶ Easy wiring access with plug-in terminals
▶ Eight detection layers including optional look-down
zone
▶ Draft and insect immunity
The ISM-BLP1-P Pet Friendly® Detector can distinguish
between signals caused by humans and signals caused by
one or two animals with a combined total weight of 13.6 kg
(30 lb).
Functions
Signal Processing
First Step Processing (FSP) almost instantly responds to
human targets without producing false alarms from other
sources. FSP adjusts the detector's sensitivity based on
signal amplitude, polarity, slope, and timing. This eliminates
the need for the installer to select the sensitivity level.
Test Features
The externally-visible alarm LED can be disabled after
installation.
Draft and Insect Immunity
The sealed optical chamber prevents drafts and insects
from affecting the detector.
Temperature Compensation
The detector adjusts its sensitivity to maintain its ability to
identify human intruders at critical temperatures.
Certifications and Approvals
Region
Certification
Europe
CE
89/336/EEC, EN55022: 1998 +A1: 2000
+A2: 2003 (ANSI C63.4: 2001),
EN50130-4: 1996 +A1: 1998 +A2: 2003,
EN61000-3-3: 1995 +A1: 2001,
EN61000-4-2: 1995 +A1: 1998 +A2:
2001, EN61000-4-3: 2002 +A1: 2002,
EN61000-4-4: 1995 +A1: 2000 +A2:
2001, EN61000-4-5: 1995 +A1: 2001,
EN61000-4-6: 1996 +A1: 2001,
EN61000-4-11:1994 +A1: 2001,
EN300440: 1996, TS 50131-2-2:2004
(Version 1)
EN50131 EN 50131-1, TS 50131-2-2 August 2004,
EN 50130-4, EN 50130-5
Belgium
INCERT
B-509-0009/a
Poland
CNBOP
83/04
Russia
GOST
IEC 60839-1-3-2001, IEC
60839-2-2-2001, IEC 60839-2-6-2001,
GOST 26342-84, GOST 27990-88
GOST 12997-84, GOST R 50009-2000,
GOST R 51317.3.2-99, GOST R
51317.3.3-99, GOST R MEK
60065-2002
USA
UL
ANSR: Intrusion Detection Units (UL639),
ANSR7: Intrusion Detection Units Certified
for Canada (cULus)
Italy
IMQ
Czech
Republic
NBU
T1207/2004
France
AFNOR
NF, A2P (262263-00)
Sweden
INTYG
Nr05-134
Ukraine
IEC 60839‑1‑3‑2001,
IEC 60839‑2‑2‑2001,
IEC 60839‑2‑6‑2001, GOST 26342‑84,
GOST  7990‑88
Europe
Complies with EN50131-2-2 Grade 2
www.boschsecurity.com 